The pump can also be operated when 
suspended by a rope.
3. Before operating the pump again ensure 
that the pump line has been completely 
emptied. When doing so vent the pump if 
necessary.
5.1
Switching ON and OFF
TP 6600
The pump will start immediately after you 
have connected it to the mains.
It will shut off after you have disconnected it 
from the mains.
All other models
After you have connected the pump to the 
mains it will be switched on (19) and off (20) 
automatically by the float switch. The point in 
time at which switching occurs depends on 
the water level.
 
Adjusting the ON and OFF times for the 
pump
The position of the float switch cable in the 
cable holder can be changed. The time inter-
val between pump switch-on and switch-off 
is thereby adjusted:
– 'Short' float switch cable: ON and OFF po-
sitions are close together. 
– 'Long' float switch cable: ON and OFF po-
sitions are far apart.
A
Caution! 
The pump may run dry and thereby be dam-
aged.
The float switch must always be able to 
move up and down to allow the pump to be 
switched on and off.
A
Danger from faulty pump!
Take appropriate measures to ensure that 
pump faults do not cause consequential 
damage through flooding of rooms. This 
must be ensured, for example, through in-
stallation of an alarm system or a reserve 
pump.
A
Danger!
Do not let the pump run against a closed 
pump line.
5.2
Shallow water suctioning 
(TPF … models)
Fasten the float switch upright to the han-
dle to enable suctioning of shallow water.
A
Risk of material damage from dry 
running of pump!
The pump can overheat and be damaged as 
the cooling function of the pumped medium 
is not active during suctioning of shallow wa-
ter. The thermal switch will react.
Only suction shallow water for a short pe-
riod of time.
Supervise the pump during suctioning of 
shallow water.
A
Danger! 
Unplug before maintaining or cleaning. 
Repair and maintenance work other than de-
scribed in this section should only be carried 
out by qualified specialists. 
6.1
Routine care 
For the pump to function perfectly at all times 
routine care is required. This also applies if 
the pump is not switched on for extended pe-
riods of time (e.g. during operation in soaka-
ways).
Cleaning the pump
1. Rinse pump with clean water. Remove 
persistent marks, e.g. algae deposits, with 
brush and dishwashing liquid. 
2. To rinse the inside of the pump:
dip pump into a container of clean water 
and switch on briefly. 
5.
Operation
19
20
6.
Pump Care