Command Overview
35
Version 2.02 – 01.04
Note1:
To setup an own sub address see configuration command sub.
Note2:
Adding an “e” to CALLEDnumber indicates that a connection to the
internal remote access of an INSYS ISDN TA shall be performed. The
protocol X.75 (ATB10) has to be used for this.
internal remote access of an INSYS ISDN TA shall be performed. The
protocol X.75 (ATB10) has to be used for this.
AT&D
DTR control
Selects the behavior of the INSYS ISDN TA, when the DTE control line DTR changes
from ON to OFF.
AT&D
Selects the behavior of the INSYS ISDN TA, when the DTE control line DTR changes
from ON to OFF.
AT&D
state of the DTR line is ignored
AT&D2
state of the control line DTR is evaluated: dropping signal on the
DTR line will disconnect an existing ISDN connection (default).
DTR line will disconnect an existing ISDN connection (default).
An incoming call will only be accepted with active DTR.
ATE
Local echo
Selects the local echo in command mode.
ATE
Selects the local echo in command mode.
ATE
no
local
echo
ATE1
local echo on in command phase (default)
AT&F
Load factory defaults
Factory defaults will be loaded, ISDN protocol settings and MSNs will not be
overwritten. (for storing in non-volatile memory please use the command AT&W).
Factory defaults will be loaded, ISDN protocol settings and MSNs will not be
overwritten. (for storing in non-volatile memory please use the command AT&W).
AT&F
setup all parameter concerning data port
AT&F1
setup all parameter including ISDN protocols, MSN settings and
passwords
passwords
ATH
Disconnect
Disconnects existing ISDN data connection after issuing the Escape sequence.
ATH
Disconnects existing ISDN data connection after issuing the Escape sequence.
ATH
[//<UUS1data>]
UUS1data
transmitted data with UUS1 signaling
ATI
Display version information
Displays different information about version number and settings:
ATI1
Displays different information about version number and settings:
ATI1
Returns internal checksum (“64“)
ATI2
Returns
“OK“
ATI3
Returns version string: "TA5.xy.z0"
ATI5
Returns selected ISDN protocol: "0 - DSS1"
ATI7
Returns
“OK“
ATI8
Returns
“ERROR”
ATI9
Returns plug and play ID string
ATI77
Returns Boot loader version string
ATI99
Returns software creation date
AT*I
Querying the alarm inputs
Response: <Input1>, <Input2>
Response: <Input1>, <Input2>
Values:
0
Input activated (LOW)
1
Input
open
(HIGH)
This command can also be executed remote.
The input state is also stored in the registers S17 and S18 (read only).
The input state is also stored in the registers S17 and S18 (read only).
AT&K
Data Flow Control
Selects the data flow control behavior of the INSYS ISDN TA while in data com-
munication phase.
AT&K
Selects the data flow control behavior of the INSYS ISDN TA while in data com-
munication phase.
AT&K
No local data flow control between the DTE and INSYS ISDN TA is
used
used
AT&K3
Local data flow control is set to hardware handshake RTS/CTS
AT&K4
Local data flow control is set to software handshake XON/XOFF
AT#M
Received CLID
Displays the call line identification (CLID) that is received with an incoming call –
Displays the call line identification (CLID) that is received with an incoming call –