Texas Instruments IC MCU 16B MSP430G2202IN20 PDIP-20 TID MSP430G2202IN20 Fiche De Données
![Texas Instruments](https://files.manualsbrain.com/attachments/b46f99d826b2b0e0e5f558c5fb6483942eb9216b/common/fit/150/50/c15ea36eb1fb1cce99a3b94668675bfc78ce832d8d727d9a7bb51a125510/brand_logo.gif)
Codes de produits
MSP430G2202IN20
DCO Frequency − MHz
0.10
1.00
10.00
0.10
1.00
10.00
DCO W
ake
T
ime
−
us
RSELx = 0...11
RSELx = 12...15
MSP430G2x32
MSP430G2x02
MSP430G2x02
SLAS723H – DECEMBER 2010 – REVISED MAY 2013
Wake-Up From Lower-Power Modes (LPM3. LPM4)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
TEST CONDITIONS
V
CC
MIN
TYP
MAX
UNIT
DCO clock wake-up time from LPM3
BCSCTL1 = CALBC1_1MHZ,
t
DCO,LPM3/4
3 V
1.5
µs
or LPM4
(1)
DCOCTL = CALDCO_1MHZ
CPU wake-up time from LPM3 or
1/f
MCLK
+
t
CPU,LPM3/4
LPM4
(2)
t
Clock,LPM3/4
(1)
The DCO clock wake-up time is measured from the edge of an external wake-up signal (for example, a port interrupt) to the first clock
edge observable externally on a clock pin (MCLK or SMCLK).
edge observable externally on a clock pin (MCLK or SMCLK).
(2)
Parameter applicable only if DCOCLK is used for MCLK.
Typical Characteristics – DCO Clock Wake-Up Time From LPM3 or LPM4
Figure 15. DCO Wake-Up Time From LPM3 vs DCO Frequency
Copyright © 2010–2013, Texas Instruments Incorporated
27