Texas Instruments On-Off Keying Coax Modem Transceiver Evalulation Module SN65HVD62EVM SN65HVD62EVM Fiche De Données

Codes de produits
SN65HVD62EVM
Page de 21
EVM Setup and Operation
12. A spectrum for higher frequency ranges can be checked. If the signal is captured then the dynamic
range of the spectrum analyzer will limit the noise floor performance. To improve the measurement a
high pass filter has been used to remove the signal content while leaving the emissions content
unaffected in the emission spectrum plot from 30MHz to 400MHz shown in
Figure 6. Emission Spectrum for 115.2kbps Transmission: 30MHz to 400MHz
13. To evaluate the effect of the voltage on the RES pin on the Tx output power, change the jumper JU4
default setting and short pins 2 and 3.
14. Change the VR1 setting to apply between 0.7V and 1.5V on the RES pin and observe the oscilloscope
and spectrum analyzer plots.
3.2.2
Rx Channel Evaluation
1. From the default jumper positions as described in Table 2, open Jumper JU13 for standalone
evaluation of either U1 or U2.
2. Set the DC power supply to source 5V with 80mA current limit and connect it between TP1 (U1_VCC)
and TP2 (GND).
3. Since JU1 is shorted by default, this means that VL supply will also get 5V. If a different supply is
required for V
L
, open JU1 and connect the second supply between TP3 (U1_VL) and TP4 (GND).
4. Leave TP6 (TXIN) floating or short it to TP3 (VL).
5. Set the waveform generator to output a 160mV p-p sine wave into a 50-
Ω
load with common mode of
1.5V.
6. Connect the waveform generator to J1.
7. Connect the oscilloscope channel 1 to JU13 pin on U1 side (RXIN).
8. Connect the oscilloscope channel 2 to TP7 (RXOUT).
9. Connect the oscilloscope channel 3 to TP8 (DIR).
10. Example waveforms with a 160mVpp sine wave input at J1 are shown in
RXOUT is low and
DIR is high indicating that the device is in Receive mode.
10
SN65HVD62 AISG On-Off Keying Modem Evaluation Module (EVM)
SLLU152 – December 2012
Copyright © 2012, Texas Instruments Incorporated