Texas Instruments Dual Phase Eco-Mode™ Step Down Converter for 40A+ Appllications using the TPS51727 TPS51727EVM TPS51727EVM Fiche De Données

Codes de produits
TPS51727EVM
Page de 22
www.ti.com
Test Procedure
Table 5. VID Bits Selection
(1)
(continued)
VID3
VID2
VID1
VID0
Vout(V)
1
1
0
1
0.925
1
1
1
1
0.875
5.5
Phase Control Selection (PCNT)
The phase control can be set by J10 (PCNT).
Default setting is jumper on pin1 and pin 2 of J10 for Auto phase control.
Table 6. Phase Control Selection
JUMPER SET TO
PHASE CONTROL
1-2 pin shorted
Auto phase control (around 12-A change to dual phase)
2-3 pin shorted
Single phase
No Jumper
Dual phase
5.6
1.5-V Output Voltage Selection (J1: 1.5-Vout Selection)
The 1.5-V output can be set by J1 (Vout Select).
Default setting: Jumper shorts on J1 to set 1.25-V output.
Table 7. 1.5-V Output Option Selection
JUMPER SET TO
OUTPUT RANGE
No Jumper
1.5-V output
Jumper shorted
4-bits VID with 0.875 V – 1.25 V
6
Test Procedure
6.1
Line/Load Regulation and Efficiency Measurement Procedure
1. Ensure that Load is set to constant resistance mode and to sink 0 Adc.
2. Ensure that the jumper provided in the EVM is set to short on J11 before Vin is applied.
3. Increase Vin from 0 V to 12 V. Using V1 to measure input voltage.
4. Remove the jumper on J11 to enable the controller.
5. Vary Load from 0 Adc to 40 Adc; Vout must remain in load regulation.
6. Vary Vin from 8 V to 14 V; Vout must remain in line regulation.
7. Put the jumper on J11 to disable the controller.
8. Decrease Load to 0 A
9. Decrease Vin to 0 V.
6.2
List of Test Points
Table 8. Functions of Each Test Points
Test Points
Name
Description
TP1
PMON
Power Monitor Output, See
.
TP2
PCNT
Phase Control Input
TP3
SW1
Phase 1 Switching Node
TP4
SW2
Phase 2 Switching Node
9
SLUU379 – November 2009
Using the TPS51727EVM, a Dual-Phase, Eco-mode™ Step-Down Power
Management IC for 40-A+ Application
Copyright © 2009, Texas Instruments Incorporated