Voltcraft LCR 4080 Digital-Multimeter, DMM, 20000 digits 41 R Fiche De Données

Codes de produits
41 R
Page de 66
Technical Data and Measuring Tolerances
A Technical Data
Display ......................................: two 4 
1
/
2
digit displays up to 19999 with sym-
bol display and measuring units
Maximum measuring rate .........: 1 measurement per second
Overload display .......................: ".OL” for Overload is displayed
Automatic Power Off APO ........: APO for Automatic Power Off, can be de-
activated, and does not function when the
interface is operated, in the MIN-MAX func-
tion and when supplied by an external
adapter.
The measuring instrument will switch off
automatically, when it is not used for about
10 minutes. To switch in on 
again, press the power button
Operating temperature..............: 0°C to +50°C
Relative humidity in air..............: 0 to 80%, not condensating
Storage temperature
(battery removed)......................: - 20°C to + 60°C, with a rel. hum. of 0 to
80% 
Temperature for guaranteed 
precision ...................................: +23°C ±5 K
Low battery signal.....................: "
" from approx. under 7 V battery
voltage 
Battery type ..............................: NEDA 1604 9V or 6F22 9V (alcaline)
or MN 1604 (=PP3)
Current consumption ................: approx. 10 mA to approx. 30 mA
External power supply ..............: nom. 12 V DC, min. 50 mA, polarity "+” inside
Fuse, defect signal....................: 100 mA, fast 250 V, usual denomination
F0.1/250V (5 x 20 mm). 
When the fuse is defective, you will hear an
uninterrupted signal sound when you switch
on the instrument, and "FUSE" will appear in
the display.
Weight.......................................: 365 g (including battery and rubber holster)
Dimensions (L x W x H).............: 192 x 91 x 52.5 mm (without rubber holster)
-
+
41