DC Voltage
Measurement Resolution Accuracy
Overload Protection
Range
400,0 mV
0,1 mV
± (0,3% rdg.+4D)
4,000 V
0,001 V
± (0,5% rdg.+3D)
40,00 V
0,01 V
± (0,5% rdg. +3D) 1050 Vrms
400,0 V
0,1 V
± (0,5% rdg. +3D) 1450 Vpeak
1000 V
1 V
± (1% rdg. + 4D)
NMRR: >50 dB (50/60 Hz)
CMRR: >120 dB (50/60 Hz, Rs=1kOhm)
Input impedance: 10 MOhm,
30 pF typical (1000 MOhm for 400-mV range)
CMRR: >120 dB (50/60 Hz, Rs=1kOhm)
Input impedance: 10 MOhm,
30 pF typical (1000 MOhm for 400-mV range)
AC Voltage (50...500 Hz)
Measurement Resolution Accuracy
Range
400 mV*
0,1 mV
± (4,0% rdg. + 5 D)
4,000 V
0,001 V
± (1,5% rdg. + 5 D)
40,00 V
0,01 V
± (1,5% rdg. + 5 D)
400,0 V
0,1 V
± (1,5% rdg. + 5 D)
1000 V
1 V
± (4,0% rdg. + 5 D)
Overload Protection: 1050 Vrms, 1450 Vpeak
CMRR: >60 dB (0...60 Hz, Rs=1kOhm)
Input impedance: 10 MOhm, 30 pF typical
CMRR: >60 dB (0...60 Hz, Rs=1kOhm)
Input impedance: 10 MOhm, 30 pF typical
* Selection by RANGE button manually and is specified
from AC 10 mV.