DC Voltage
Measurement Resolution Accuracy 
Overload Protection
Range 
400,0 mV 
0,1 mV 
± (0,3% rdg.+4D)   
4,000 V 
0,001 V 
± (0,5% rdg.+3D)   
40,00 V 
0,01 V 
± (0,5% rdg. +3D)  1050 Vrms
400,0 V 
0,1 V 
± (0,5% rdg. +3D)  1450 Vpeak
1000 V 
1 V 
± (1%  rdg. + 4D)   
NMRR: >50 dB (50/60 Hz)
CMRR: >120 dB (50/60 Hz, Rs=1kOhm)
Input impedance: 10 MOhm, 
30 pF typical (1000 MOhm for 400-mV range)
AC Voltage (50...500 Hz)
Measurement Resolution  Accuracy
Range  
400 mV* 
0,1 mV
± (4,0% rdg. + 5 D)  
4,000 V 
0,001 V 
± (1,5% rdg. + 5 D)   
40,00 V 
0,01 V 
± (1,5% rdg. + 5 D) 
400,0 V 
0,1 V 
± (1,5% rdg. + 5 D)   
1000 V 
1 V 
± (4,0% rdg. + 5 D)
Overload Protection:   1050 Vrms, 1450 Vpeak
CMRR: >60 dB (0...60 Hz, Rs=1kOhm)
Input impedance: 10 MOhm, 30 pF typical 