MPC8309 PowerQUICC II Pro Integrated Communications Processor Family Hardware Specifications, Rev. 2
Freescale Semiconductor
23
 
Ethernet and MII management
8.2
MII and RMII AC timing specifications
The AC timing specifications for MII and RMII are presented in this section. 
8.2.1
MII AC timing specifications
This section describes the MII transmit and receive AC timing specifications.
8.2.1.1
MII transmit AC timing specifications
The following table provides the MII transmit AC timing specifications.
Table 19. MII and RMII DC electrical characteristics
Parameter
Symbol
Conditions
Min
Max
Unit
Supply voltage 3.3 V
OV
DD
 
3
3.6
V
Output high voltage
V
OH
I
OH
= –4.0 mA
OV
DD
= Min
2.40
OV
DD
+ 0.3
V
Output low voltage
V
OL
I
OL
= 4.0 mA
OV
DD
= Min
GND 0.
50
V
Input high voltage
V
IH
2.0
OV
DD
+ 0.3
V
Input low voltage
V
IL
–0.3
0.90
V
Input current
I
IN
0 V
≤ V
IN
≤ OV
DD
±5
μA
Table 20. MII transmit AC timing specifications
At recommended operating conditions with OV
DD 
of 3.3 V ± 300mV.
Parameter/Condition
Symbol
1
Min
Typical
Max
Unit
TX_CLK clock period 10 Mbps
t
MTX
400
ns
TX_CLK clock period 100 Mbps
t
MTX
40
ns
TX_CLK duty cycle
t
MTXH
/t
MTX
35
65
%
TX_CLK to MII data TXD[3:0], TX_ER, TX_EN delay 
t
MTKHDX
1
5
15
ns
TX_CLK data clock rise V
IL
(min) to V
IH
(max)
t
MTXR
1.0
4.0
ns
TX_CLK data clock fall V
IH
(max) to V
IL
(min) t
MTXF
1.0
4.0
ns
Note:
1. The symbols used for timing specifications follow the pattern of t
(first two letters of functional block)(signal)(state)(reference)(state)
 for 
inputs and t
(first two letters of functional block)(reference)(state)(signal)(state)
 for outputs. For example, t
MTKHDX
 symbolizes MII transmit 
timing (MT) for the time t
MTX
 clock reference (K) going high (H) until data outputs (D) are invalid (X). Note that, in general, 
the clock reference symbol representation is based on two to three letters representing the clock of a particular functional. 
For example, the subscript of t
MTX
 represents the MII(M) transmit (TX) clock. For rise and fall times, the latter convention is 
used with the appropriate letter: R (rise) or F (fall).