Freescale Semiconductor MPC830x PowerQUICC II Pro Processor Evaluation Kit MPC8309-KIT MPC8309-KIT Fiche De Données

Codes de produits
MPC8309-KIT
Page de 79
MPC8309 PowerQUICC II Pro Integrated Communications Processor Family Hardware Specifications, Rev. 2
Freescale Semiconductor
27
 
Ethernet and MII management
The following figure shows the RMII receive AC timing diagram.
Figure 16. RMII receive AC timing diagram
8.3
Ethernet management interface electrical characteristics
The electrical characteristics specified here apply to MII management interface signals MDIO 
(management data input/output) and MDC (management data clock). The electrical characteristics for 
MII, and RMII are specified in 
8.3.1
MII management DC electrical characteristics
MDC and MDIO are defined to operate at a supply voltage of 3.3 V. The DC electrical characteristics for 
MDIO and MDC are provided in the following table.
8.3.2
MII management AC electrical specifications
The following table provides the MII management AC timing specifications.
Table 24. MII management DC electrical characteristics when powered at 3.3 V
Parameter
Symbol
Conditions
Min
Max
Unit
Supply voltage (3.3 V)
OV
DD
3
3.6
V
Output high voltage
V
OH
I
OH
= –1.0 mA
OV
DD
= Min
2.40
OV
DD
 + 0.3
V
Output low voltage
V
OL
I
OL
= 1.0 mA
OV
DD
= Min
GND 0.
50
V
Input high voltage
V
IH
2.00
V
Input low voltage
V
IL
0.80
V
Input current
I
IN
0 V
≤ V
IN
≤ OV
DD
±5
μA
Table 25. MII management AC timing specifications
At recommended operating conditions with OV
DD
 is 3.3 V ± 300mV. 
Parameter/Condition
Symbol
1
Min
Typical
Max
Unit
Note
MDC frequency 
f
MDC
2.5
MHz
MDC period
t
MDC
400
ns
MDC clock pulse width high
t
MDCH
32
ns
REF_CLK
RXD[1:0]
t
RMRDXKH
t
RMX
t
RMXH
t
RMXR
t
RMXF
CRS_DV
RX_ER
t
RMRDVKH
Valid Data