Functions 
June 06 
35 
5.9  Data Transmit Controller (Idle Connection Control) 
The Data Transmit Control (DTC) is a function integrated in 
the firmware which monitors the data transmission in 
online mode. This function prevents the modem to stay 
online for an unlimited amount of time, although no data is 
being transmitted anymore. 
5.9.1  Activation 
The activation takes place in the S15 registry. Any time pe-
riod between 1 and 255 seconds may be set.  
5.9.2  Mode of Operation for the “Timer” 
The timer will run immediately after the modem goes off-
hook. After the set time has been reached, a RESET is per-
formed.  
The timer is reset by each byte that is sent via the serial in-
terface. 
Note: 
The timer will run immediately after the modem 
goes off-hook. We therefore strongly recommend 
to not setting any times below 30 seconds.
 
In remote mode, idle connection control at the mo-
dem must be deactivated to prevent the connec-
tion from being interrupted after the timer has run 
out. 
 
The remote data transmission will not reset the 
timer. 
ATS15=<n>