Hameg HO730 Ethernet/USB Dual Interface Compatible with HM1008, HM1508, HM1008-2, HM1500-2, HM1508-2, HM2005-2, HM2008 a 26-0730-0000 Fiche De Données

Codes de produits
26-0730-0000
Page de 16
2
Änderungen vorbehalten
G e n e r a l   i n f o r m a t i o n   r e g a r d i n g   t h e   C E   m a r k i n g          
General information regarding the CE marking
HAMEG instruments fulfi ll the regulations of the EMC directive. The 
conformity test made by HAMEG is based on the actual generic- and 
product standards. In cases where different limit values are applicable, 
HAMEG applies the severer standard. For emission the limits for 
residential, commercial and light industry are applied. Regarding the 
immunity (susceptibility) the limits for industrial environment have 
been used.
The measuring- and data lines of the instrument have much infl uence 
on emmission and immunity and therefore on meeting the acceptance 
limits. For different applications the lines and/or cables used may 
be different. For measurement operation the following hints and 
conditions regarding emission and immunity should be observed:
1. Data cables
For the connection between instruments resp. their interfaces and 
external devices, (computer, printer etc.) suffi ciently screened cables 
must be used. Without a special instruction in the manual for a reduced 
cable length, the maximum cable length of a dataline must be less than 
3 meters and not be used outside buildings. If an interface has several 
connectors only one connector must have a connection to a cable.
Basically interconnections must have a double screening. For IEEE-bus 
purposes the double screened cables HZ72S and HZ72L from HAMEG 
are suitable.
2. Signal cables
Basically test leads for signal interconnection between test point and 
instrument should be as short as possible. Without instruction in the 
manual for a shorter length, signal lines must be less than 3 meters 
and not be used outside buildings.
Signal lines must screened (coaxial cable - RG58/U). A proper ground 
connection is required. In combination with signal generators double 
screened cables (RG223/U, RG214/U) must be used.
3. Infl uence on measuring instruments.
Under the presence of strong high frequency electric or magnetic fi elds, 
even with careful setup of the measuring equipment an infl uence of 
such signals is unavoidable.
This will not cause damage or put the instrument out of operation. Small 
deviations of the measuring value (reading) exceeding the instruments 
specifi cations may result from such conditions in individual cases.
HAMEG Instruments GmbH
KONFORMITÄTSERKLÄRUNG
DECLARATION OF CONFORMITY
DECLARATION DE CONFORMITE
DECLARACIÓN DE CONFORMIDAD
Hersteller / Manufacturer / Fabricant / Fabricante: 
HAMEG Instruments GmbH · Industriestraße 6 · D-63533 Mainhausen 
Die HAMEG Instruments GmbH bescheinigt die Konformität für das Produkt 
The HAMEG Instruments GmbH herewith declares conformity of the product 
HAMEG Instruments GmbH déclare la conformite du produit 
HAMEG Instruments GmbH certifi ca la conformidad para el producto
Bezeichnung:  
Ethernet/USB-Interface
Product name:  
Ethernet/USB Interface
Designation: Interface 
Ethernet/USB
Descripción: Interfaz 
Ethernet/USB
Typ / Type / Type / Tipo: 
HO730
mit / with / avec / con: 
HM1008, HM1508, HM1508-2, HM2008
Optionen / Options / 
Options / Opciónes: 
mit den folgenden Bestimmungen / with applicable regulations /  
avec les directives suivantes / con las siguientes directivas:
EMV Richtlinie 89/336/EWG ergänzt durch 91/263/EWG, 92/31/EWG 
EMC Directive 89/336/EEC amended by 91/263/EWG, 92/31/EEC 
Directive EMC 89/336/CEE amendée par 91/263/EWG, 92/31/CEE 
Directiva EMC 89/336/CEE enmendada por 91/263/CEE, 92/31/CEE
Niederspannungsrichtlinie 73/23/EWG ergänzt durch 93/68/EWG 
Low-Voltage Equipment Directive 73/23/EEC amended by 93/68/EEC
Directive des equipements basse tension 73/23/CEE amendée par 93/68/CEE
Directiva de equipos de baja tensión 73/23/CEE enmendada por 93/68/EWG
Angewendete harmonisierte Normen / Harmonized standards applied / 
Normes harmonisées utilisées / Normas armonizadas utilizadas:
Sicherheit / Safety / Sécurité / Seguridad:
EN 61010-1:2001 / IEC (CEI) 1010-1:2001
Überspannungskategorie / Overvoltage category / Catégorie de surtension / 
Categoría de sobretensión: II
Verschmutzungsgrad / Degree of pollution / Degré de pollution / Nivel de 
polución: 2
Elektromagnetische Verträglichkeit / Electromagnetic compatibility / 
Compatibilité électromagnétique / Compatibilidad electromagnética: 
EN 61326-1/A1: Störaussendung / Radiation / Emission: Tabelle / table / 
tableau 4; Klasse / Class / Classe / classe B. 
Störfestigkeit / Immunity / Imunitee / inmunidad: 
Tabelle / table / tableau / tabla A1. 
EN 61000-3-2/A14: Oberschwingungsströme / Harmonic current emissions 
/ Émissions de courant harmonique / emisión de corrientes armónicas: 
Klasse / Class / Classe / clase D.
EN 61000-3-3: Spannungsschwankungen u. Flicker / Voltage fl uctuations 
and fl icker / Fluctuations de tension et du fl icker / fl uctuaciones de tensión 
y fl icker.
Datum / Date / Date / Fecha   
26. 09. 2006
 
Unterschrift / Signature / Signatur / Signatura
 Manuel 
Roth
 Manager