MEASURING GROUND CURRENT 
07
14
0-
0
07
GND
GND
ANALOG DEVICES
ADP121-xx-EVALZ
VOUT
GND
C2
C1
U1
VIN
GND
EN
J1
VOLTAGE SOURCE
LOAD
AMMETER
+
+
 
Figure 11. Ground Current Measurement, TSOT 
07
14
0-
0
16
LOAD
AMMETER
+
+
VOLTAGE SOURCE
 
Figure 12. Ground Current Measurement, WLCSP 
Figure 11 and Figure 12 show the evaluation board connected 
to a voltage source and an ammeter for ground current measure-
ments. A resistor can be used as the load for the regulator. 
Ensure that the resistor has a power rating that is adequate to 
handle the power expected to be dissipated across it. An electronic 
load can be used as an alternative. Ensure that the voltage source 
used can supply enough current for the expected load levels. 
Use the following steps to connect to a voltage source and 
ammeter: 
1.  Connect the positive terminal (+) of the voltage source to 
the VIN pad on the evaluation board.  
2.  Connect the positive terminal (+) of the ammeter to one of 
the GND pads of the evaluation board.  
3.  Connect the negative terminal (−) of the ammeter to the 
negative (−) terminal of the voltage source.  
4.  Connect a load between the negative (−) terminal of the 
voltage source and the VOUT pad of the evaluation board.  
The voltage source can now be turned on. If J1 or J2 is inserted 
(connecting EN to VIN for automatic startup), the regulator 
powers up.