MEASURING OUTPUT VOLTAGE 
GND
GND
ANALOG DEVICES
ADP121-xx-EVALZ
VOUT
GND
C2
C1
U1
VIN
GND
EN
J1
VOLTAGE SOURCE
07
140
-00
3
VOLTMETER
LOAD
+
+
 
Figure 5. Output Voltage Measurement, TSOT 
 
07
14
0-
01
5
VOLTMETER
+
+
VOLTAGE SOURCE
LOAD
 
Figure 6. Output Voltage Measurement, WLCSP 
Figure 5 anFigure 6 show how the evaluation board can be 
connected to a voltage source and a voltmeter for basic output 
voltage accuracy measurements. A resistor can be used as the 
load for the regulator. Ensure that the resistor has a power 
rating adequate to handle the power expected to be dissipated 
across it. An electronic load can also be used as an alternative. 
Ensure that the voltage source can supply enough current for 
the expected load levels. 
Use the following steps to connect to a voltage source and 
voltmeter: 
1.  Connect the negative terminal (−) of the voltage source to 
one of the GND pads on the evaluation board.  
2.  Connect the positive terminal (+) of the voltage source to 
the VIN pad of the evaluation board.  
3.  Connect a load between the VOUT pad and one of the 
GND pads.  
4.  Connect the negative terminal (−) of the voltmeter to one 
of the GND pads. 
5.  Connect the positive terminal (+) of the voltmeter to the 
VOUT pad.  
The voltage source can now be turned on. If J1 or J2 is inserted 
(connecting EN to VIN for automatic startup), the regulator 
powers up. 
If the load current is large, the user needs to connect the 
voltmeter as close as possible to the output capacitor to  
reduce the effects of IR drops.