Rev. A | Page 8 of 44 
ABSOLUTE MAXIMUM RATINGS 
 
Table 5.  
Parameter Rating 
ELECTRICAL  
AVDD to AGND 
−0.3 V to +2.0 V 
DRVDD to DRGND 
−0.3 V to +3.9 V 
AGND to DRGND 
−0.3 V to +0.3 V 
AVDD to DRVDD 
−3.9 V to +2.0 V 
D0 through D11 to DRGND 
−0.3 V to DRVDD + 0.3 V 
DCO to DRGND 
−0.3 V to DRVDD + 0.3 V 
OR to DRGND 
−0.3 V to DRVDD + 0.3 V 
CLK+ to AGND 
−0.3 V to +3.9 V 
CLK− to AGND 
−0.3 V to +3.9 V 
VIN+ to AGND  
−0.3 V to AVDD + 1.3 V 
VIN− to AGND 
−0.3 V to AVDD + 1.3 V 
VREF to AGND 
−0.3 V to AVDD + 0.2 V 
SENSE to AGND 
−0.3 V to AVDD + 0.2 V 
REFT to AGND 
−0.3 V to AVDD + 0.2 V 
REFB to AGND  
−0.3 V to AVDD + 0.2 V 
SDIO/DCS to DRGND 
−0.3 V to DRVDD + 0.3 V 
PDWN to AGND 
−0.3 V to +3.9 V 
CSB to AGND  
−0.3 V to +3.9 V 
SCLK/DFS to AGND  
−0.3 V to +3.9 V 
OEB to AGND 
−0.3 V to +3.9 V 
ENVIRONMENTAL  
Storage Temperature Range 
–65°C to +125°C 
Operating Temperature Range 
–40°C to +85°C 
Lead Temperature  
(Soldering 10 Sec) 
300°C 
Junction Temperature 
150°C 
 
Stresses above those listed under Absolute Maximum Ratings 
may cause permanent damage to the device. This is a stress 
rating only; functional operation of the device at these or any 
other conditions above those indicated in the operational 
section of this specification is not implied. Exposure to absolute 
maximum rating conditions for extended periods may affect 
device reliability. 
THERMAL RESISTANCE 
The exposed paddle must be soldered to the ground plane for 
the LFCSP package. Soldering the exposed paddle to the 
customer board increases the reliability of the solder joints, 
maximizing the thermal capability of the package. 
 
Table 6.  
Package Type 
θ
JA
θ
JC
Unit 
48-lead LFCSP (CP-48-3) 
26.4 
2.4 
°C/W 
 
Typical θ
JA
 and θ
JC
 are specified for a 4-layer board in still air. 
Airflow increases heat dissipation, effectively reducing θ
JA
. In 
addition, metal in direct contact with the package leads from 
metal traces, and through holes, ground, and power planes, 
reduces the θ
JA
.  
 
ESD CAUTION 
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on the 
human body and test equipment and can discharge without detection. Although this product features 
proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy 
electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance 
degradation or loss of functionality.