Analog Devices ADP2120 Evaluation Board ADP2120-EVALZ ADP2120-EVALZ Fiche De Données

Codes de produits
ADP2120-EVALZ
Page de 8
UG-188 
Evaluation Board User Guide
 
Rev. 0 | Page 4 of 8 
scope to an ac coupling, 10 mV/division, 2 μs/division time base 
and 20 MHz bandwidth.  
A standard oscilloscope probe has a long wire ground clip. For 
high frequency measurements, this ground clip picks up high 
frequency noise and injects it into the measured output ripple. 
Figure 3 shows an easy way to measure the output ripple prop-
erly. It requires removing the oscilloscope probe sheath and 
wrapping a nonshielded wire around the oscilloscope probe.  
By keeping the ground lengths of the oscilloscope probe as 
short as possible, true ripple can be measured. 
Output Voltage Change 
The ADP2119/ADP2120 evaluation board output is preset to 
1.2 V; however, the output voltage can be adjusted using the 
following equation: 
+
×
=
4
3
4
V
6
.
0
R
R
R
V
OUT
 
09314
-0
03
 
Figure 3. Output Ripple Measurement