SAM4S Series [DATASHEET]
Atmel-11100G-ATARM-SAM4S-Datasheet_27-May-14
36.8.19 USART Number of Errors Register
Name:
US_NER
Address:
0x40024044 (0), 0x40028044 (1)
Access:
Read-only
 
This register is relevant only if USART_MODE = 0x4 or 0x6 in “USART Mode Register” on page 798.
• NB_ERRORS: Number of Errors
Total number of errors that occurred during an ISO7816 transfer. This register automatically clears when read.
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
NB_ERRORS