38.6.1 PWM Clock Generator
Figure 38-2. Functional View of the Clock Generator Block Diagram 
The PWM master clock (MCK) is divided in the clock generator module to provide different clocks available for all
channels. Each channel can independently select one of the divided clocks.
The clock generator is divided in three blocks:
a modulo n counter which provides 11 clocks: F
MCK
, F
MCK
/2, F
MCK
/4, F
MCK
/8, F
MCK
/16, F
MCK
/32, F
MCK
/64, 
F
MCK
/128, F
MCK
/256, F
MCK
/512, F
MCK
/1024 
two linear dividers (1, 1/2, 1/3, ... 1/255) that provide two separate clocks: clkA and clkB
Each linear divider can independently divide one of the clocks of the modulo n counter. The selection of the clock to be
divided is made according to the PREA (PREB) field of the PWM Clock register (PWM_CLK). The resulting clock clkA
(clkB) is the clock selected divided by DIVA (DIVB) field value.
After a reset of the PWM controller, DIVA (DIVB) and PREA (PREB) are set to 0. This implies that after reset clkA (clkB)
are turned off.
At reset, all clocks provided by the modulo n counter are turned off except clock ”MCK”. This situation is also true when
the PWM master clock is turned off through the Power Management Controller.
CAUTION:
Before using the PWM macrocell, the programmer must first enable the PWM clock in the Power Management 
Controller (PMC).
modulo n counter
MCK/2
MCK/4
MCK/16
MCK/32
MCK/64
MCK/8
Divider A
clkA
DIVA
PWM_MR
MCK
MCK/128
MCK/256
MCK/512
MCK/1024
PREA
Divider B
clkB
DIVB
PWM_MR
PREB
MCK