Mikroelektronika MIKROE-350 Fiche De Données

Page de 526
Library Routines
- Spi_Ethernet_Init 
- Spi_Ethernet_Enable 
- Spi_Ethernet_Disable 
- Spi_Ethernet_doPacket 
- Spi_Ethernet_putByte 
- Spi_Ethernet_putBytes 
- Spi_Ethernet_putString 
- Spi_Ethernet_putConstString 
- Spi_Ethernet_putConstBytes 
- Spi_Ethernet_getByte 
- Spi_Ethernet_getBytes 
- Spi_Ethernet_UserTCP
- Spi_Ethernet_UserUDP
Spi_Ethernet_Init
369
MIKROELEKTRONIKA
- SOFTWARE AND HARDWARE SOLUTIONS FOR EMBEDDED WORLD
Libraries
mikroBasic PRO for AVR
CHAPTER 6
Prototype
sub procedure Spi_Ethernet_Init(dim mac as ^bytedim ip as
^byte
dim fullDuplex as byte)
Returns
Nothing.
Description
This is MAC module routine. It initializes 
ENC28J60
controller. This function is
internaly splited into 2 parts to help linker when coming short of memory.
ENC28J60
controller settings (parameters not mentioned here are set to default): 
- receive buffer start address : 
0x0000
- receive buffer end address : 
0x19AD
- transmit buffer start address: 
0x19AE
- transmit buffer end address : 
0x1FFF
- RAM buffer read/write pointers in auto-increment mode. 
- receive filters set to default: CRC + MAC Unicast + MAC Broadcast in OR mode. 
- flow control with TX and RX pause frames in full duplex mode. 
- frames are padded to 
60
bytes + CRC. 
- maximum packet size is set to 
1518
- Back-to-Back Inter-Packet Gap: 
0x15
in full duplex mode; 
0x12
in half duplex mode. 
- Non-Back-to-Back Inter-Packet Gap: 
0x0012
in full duplex mode; 
0x0C12
in 
half duplex mode. 
- Collision window is set to 
63
in half duplex mode to accomodate some  
ENC28J60
revisions silicon bugs. 
- CLKOUT output is disabled to reduce EMI generation. 
- half duplex loopback disabled. 
- LED configuration: default (LEDA-link status, LEDB-link activity).