Atmel Xplained Pro Evaluation Kit for the ATSAMD21J18A Microcontroller ATSAMD21-XPRO ATSAMD21-XPRO Fiche De Données

Codes de produits
ATSAMD21-XPRO
Page de 1018
999
Atmel | SMART SAM D21 [DATASHEET]
Atmel-42181C–SAM-D21_Datasheet–07/2014
Time-out (CTRLA.LOWTOUT) is disabled. When SCTRLA.LOWTOUT=0, the 
GCLK_SERCOM_SLOW is not requested. Errata reference: 12003
Fix/Workaround:
To use the Master or Slave SCL low extend time-outs, enable the SCL Low Time-out 
(CTRLA.LOWTOUT=1).
39.3.6 TCC
1 - With blanking enabled, a recoverable fault that occurs during the first increment of a 
rising TCC is not blanked. Errata reference: 12519
Fix/Workaround:
None
2 - In Dual slope mode a Retrigger Event does not clear the TCC counter. Errata reference: 
12354
Fix/Workaround:
None
3 - In two ramp mode, two events will be generated per cycle, one on each ramp’s end. 
EVCTRL.CNTSEL.END cannot be used to identify the end of a double ramp cycle. Errata 
reference: 12224
Fix/Workaround:
None
4 - If an input event triggered STOP action is performed at the same time as the counter 
overflows, the first pulse width of the subsequent counter start can be altered with one 
prescaled clock cycle. Errata reference: 12107
Fix/Workaround:
None
5 - When the RUNSTDBY bit is written after the TCC is enabled, the respective TCC APB bus 
is stalled and the RUNDSTBY bit in the TCC CTRLA register is not enabled-protected. Errata 
reference: 12477
Fix/Workaround:
None.
6 - TCC fault filtering on inverted fault is not working. Errata reference: 12512
Fix/Workaround:
Use only non-inverted faults.
7 - When waking up from the STANDBY power save mode, the SYNCBUSY.CTRLB and 
SYNCBUSY.STATUS bits may be locked to 1. Errata reference: 12227
Fix/Workaround: