Linear Technology LTC2924 Quad Supply Sequencer DC818A DC818A Fiche De Données

Codes de produits
DC818A
Page de 22
LTC2924
4
2924fb
elecTrical characTerisTics
Note 1: Stresses beyond those listed under Absolute Maximum Ratings 
may cause permanent damage to the device. Exposure to any Absolute 
Maximum Rating condition for extended periods may affect device 
reliability and lifetime.
Note 2: Hysteresis current must be 500nA minimum. Hysteresis current  
may exceed 50µA, but accuracy is not guaranteed.
Note 3: HYS/CFG pin must be pulled to GND or V
CC
 with an external  
resistor. See Applications Information for details. 
SYMBOL
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNITS
DONE Characteristics
R
D(LO)
 
DONE Pin Pull-Down Resistance to GND 
DONE = Low, I = 2mA
l
100 
Ω 
I
D(HI) 
DONE Pin Off Leakage Current 
DONE = High
l
15 
µA 
FAULT Characteristics
R
FAULT (LO)
 
FAULT Pin Pull-Down Resistance to GND 
FAULT Being Pulled Low Internally,  
I = 2mA
l
400 
Ω
I
FAULT(HI)
 
FAULT Pin Off Leakage Current 
FAULT High
l
µA 
V
FAULT(HI)
 
Voltage Above Which an Externally Generated 
FAULT Condition Will Not be Detected
l
1.6 
V
FAULT(LO)
 
Voltage Below Which an Externally Generated 
l
0.6 
FAULT Condition Will be Detected 
R
F(EXT)
 
External Pull-Up Resistance 
l
10 
k
Ω 
t
FAULT
 
Externally Commanded FAULT Below V
FAULT(LO)
 
to OUT1-OUT4 Pull-Down On Delay
l
µs 
t
FAULT(MIN)
 
Externally Commanded FAULT Minimum Time  
Below V
FAULT(LO
)
(Note 4) 
µs
 The 
l
 denotes the specifications which apply over the full operating 
temperature range, otherwise specifications are at T
A
 = 25°C. V
CC
 = 3V to 6V, unless otherwise noted.
Note 4: Determined by design, not production tested. External circuits 
pulling down on the FAULT pin must maintain the signal below V
FAULT(LO)
 
for ≥1µs.
Note 5: Internal circuits may drive the OUTn pins higher than the Absolute 
Maximum Ratings.
Note 6: R
IN
 is the parallel combination of the two resistors forming the 
resistive divider connected to the ON and IN1-IN4 pins.