Installation manual DSZY5 
 
 
Make sure the actuator ist not connected electrically when installed. 
Make sure you use the correct AC voltage. 
Actuator force must not be over loaded. Please refer to the model 
number and it’s force specification. 
To avoid over load disconnect the actuator if the current exceed 
it’s maximum rating. 
 
The load should be centered on the operating direction. Side load 
is NOT good for the actuator.  
In case the actuator rod is exposed to side load the service life 
time will be reduced. 
 
 
 
 
 
load – current - diagram 
load – speed - diagram 
 
 
 
 
 
 
 
Please make sure to use the right power supply as 
mentioned on the actuator. 
 
The rod will extend if the red and white wires are connected 
to the single phase AC-voltage. For the retract function 
there is to change the white wire against the black one. 
 
Moving is stopping automatically by the integrated 
endswitches. Both endswitches can adjust by the user 
himselfe.
 
 
 
 