5 Funct
ion
s
18
5.5
Level locking via a code
As an alternative to the logic input, level locking can be set
via a code (logic input has priority).
h Set the code with 
q
 + 
d
 (>5sec) in the
normal display
Level locking via the logic input will inhibit the parameter and configuration levels (corresponds
to code 011).
1
The values at the operating level can only be displayed but not modified. 
Code Operating level
Parameter level
Configuration level
000
enabled
enabled
enabled
001
enabled
enabled
inhibited
011
enabled
inhibited
inhibited
111
inhibited
1
inhibited