Siemens SPS starter kit 6ED1057-3BA00-0AA8 12 Vdc, 24 Vdc 6ED1057-3BA00-0AA8 Fiche De Données
Codes de produits
6ED1057-3BA00-0AA8
LOGO! functions
4.4 Special functions list - SF
LOGO!
Manual, 06/2014, A5E33039675
Manual, 06/2014, A5E33039675
145
● Edge-triggered wiping relay (Page 148)(current time Ta)
● Asynchronous pulse generator (Page 150)(current time Ta)
● Stairway lighting switch (Page 154)(current time Ta)
● Multiple function switch (Page 156)(current time Ta)
● Stopwatch (Page 171)(actual value AQ)
● Threshold trigger (Page 180) (actual value Fre)
Select the required function by the block number. The timebase is configurable. For
● Asynchronous pulse generator (Page 150)(current time Ta)
● Stairway lighting switch (Page 154)(current time Ta)
● Multiple function switch (Page 156)(current time Ta)
● Stopwatch (Page 171)(actual value AQ)
● Threshold trigger (Page 180) (actual value Fre)
Select the required function by the block number. The timebase is configurable. For
Timing diagram
Functional description
The 0 to 1 signal transition at input Trg triggers the current time T
a
. LOGO! sets output Q
when T
a
= T. A further signal at input Trg does not influence the time T
a
.
LOGO! resets the output and the time T
a
with the next 1 signal at input R.
If the block is retentive, LOGO! resets output Q and the expired time to the values before a
power failure; if the block is not retentive, LOGO! resets output Q and the expired time to
defaults after a power failure.