Bourns PTC fuse Current I(H) 0.25 A 240 V (L x W x H) 27.6 x 10 x 3.8 mm MF-RM025/240-2 1 pc(s) MF-RM025/240-2 Fiche De Données
Codes de produits
MF-RM025/240-2
IEC
EIA
Dimensions
Dimension Description
Mark
Mark
Dimensions
Tolerance
Carrier tape width
W W
18
-0.5/+1.0
(.709)
(-0.02/+.039)
Hold down tape width
W0
W4
11
min.
(.433)
Hold down tape
No protrusion
Top distance between tape edges
W2
W6
3
max.
(.118)
Sprocket hole position
W1
W5
9
-0.5/+0.75
(.354)
(-0.02/+0.03)
Sprocket hole diameter
D0
D0
4
±0.2
(.157)
(±.079)
Abscissa to plane (MF-RM005/240~MF-RM016/240)
H H
18.5
±3.0
(.728)
(±.118)
Abscissa to plane (MF-RM025/240~MF-RM055/240)
H0
H0
16
±0.5
(.63)
(±.02)
Abscissa to top (MF-RM005/240~MF-RM016/240)
H1
H1
32.2
max.
(1.268)
Abscissa to top (MF-RM025/240~MF-RM055/240)
H1
H1
45.0
max.
(1.772)
Overall width w/lead protrusion (MF-RM005/240~MF-RM016/240)
C1
43.2
max.
(1.701)
Overall width w/lead protrusion (MF-RM025/240~MF-RM055/240)
C1
56.0
max.
(2.205)
Overall width w/o lead protrusion (MF-RM005/240~MF-RM016/240)
C2
42.5
max.
(1.673)
Overall width w/o lead protrusion (MF-RM025/240~MF-RM055/240)
C2
56.0
max.
(2.205)
Lead protrusion
I1
L1
1.0
max.
(.039)
Protrusion of cutout
L L
11
max.
(.433)
Protrusion beyond hold-down tape
I2
I2 Not
specifi
ed
Sprocket hole pitch
P0
P0
12.7 ±0.3
(.500)
(±.012)
Pitch tolerance
20 consecutive
±1
(±.039)
Device pitch (MF-RM005/240-MF-RM040/240)
12.7
±0.3
(.500)
(±.012)
Device pitch (MF-RM055/240)
25.4
±0.6
(1.00)
(±.024)
Tape thickness
t t
0.9
max.
(.035)
Tape thickness with splice (MF-RM005/240~MF-RM040/240)
t1
1.5
max.
(.059)
Tape thickness with splice (MF-RM055/240)
t1
2.3
max.
(.091)
Splice sprocket hole alignment
0
±0.3
(±.012)
Body lateral deviation
Δh
Δh
0
±1
(±.039)
Body tape plane deviation
Δp
Δp
0
±0.3
(±.012)
Lead seating plane deviation
ΔP1
P1
3.81
±0.7
(.015)
(±.028)
Lead spacing
F F
5.08
+0.8/-0.5
(.200)
(+.031/-.020)
MF-RM Series Tape and Reel Specifi cations
Specifi cations are subject to change without notice.
Customers should verify actual device performance in their specifi c applications.
Customers should verify actual device performance in their specifi c applications.
Devices taped using EIA468–B/IEC60286-2 standards. See table below and Figures 1 and 2 for details.
DIMENSIONS:
MM
(INCHES)