Nkk Switches SK12BG30 Key Switch, SK12BG30 Fiche De Données

Codes de produits
SK12BG30
Page de 6
F
Series SK
Process Sealed Keylocks
www.nkk.com
F20
Indicators
Accessories
Supplement
Tactiles
Keylocks
Rotaries
Pushbuttons
Illuminated PB
Slides
Programmable
Touch
Tilt
 
Rockers
Toggles
Electrical Capacity (Resistive Load) 
 
Logic Level: 
  0.4VA maximum @ 28V AC/DC maximum  
 
 
(Applicable Range 0.1mA ~ 0.1A @ 20mV ~ 28V) 
 
 
See Supplement section to find explanation of operating range  
Other Ratings
 
Contact Resistance:  
80 milliohms maximum
 
Insulation Resistance: 
100 megohms minimum @ 500V DC
 
Dielectric Strength: 
500V AC minimum for 1 minute minimum
 
Mechanical Life: 
30,000 cycles minimum
 
Electrical Life: 
10,000 cycles minimum 
 
Nominal Operating Torque: 
.026Nm (.234 lb
in) for momentary action models 
 
 
.020Nm (.182 lb
in) for maintained action models 
 
Contact Timing: 
Break-before-make
 
Angle of Throw:    90° for 2-position & 45° for 3-position 
Materials & Finishes
 
Boot: 
Polyvinyl chloride    
 
 
 
 
 
 
 
 
 
Key: 
Brass alloy with bright nickel plating; 
 
 
brass alloy with bright nickel plating & ABS resin handle  
 
Tumbler Barrel: 
Polyacetal  
 
Bushing: 
Zinc alloy with nickel plating 
  
Bracket: 
Steel with tin plating 
 
Base: 
Glass fiber reinforced polyamide 
 
Movable Contactor: 
Beryllium copper with gold plating
 
Stationary Contacts: 
Copper with gold plating
 
Terminals: 
Brass with tin plating 
Environmental Data
 Operating Temperature Range: 
–25°C through +70°C (–13°F through +158°F)
 
Humidity: 
90 ~ 95% humidity for 240 hours @ 40°C (104°F)
 
Vibration: 
10 ~ 55Hz with peak-to-peak amplitude of 1.5mm traversing the frequency range & returning  
 
 
in 1 minute; 3 right angled directions for 2 hours
 
Shock: 
50G (490m/s
2
) acceleration (tested in 6 right angled directions, with 5 shocks in each direction)
PCB Processing
 
Soldering:  
Wave Soldering recommended:  See Profile B in Supplement section.  
 
 
Manual Soldering:  See Profile B in Supplement section.  
 
Cleaning: 
Automated cleaning.  Boot must be on switch during processing. 
 
 
See Cleaning specifications in Supplement section. 
Standards & Certifications
 
 
These SK Series devices have not been tested for UL recognition or CSA certification. 
 
 
These switches are designed for use in a low-voltage, low-current, logic-level circuit.  
 
 
When used as intended in a logic-level circuit, the results do not produce hazardous energy.
General 
Specifications