Buffalo LinkStation 441D 4TB LS441D0404-EU Fiche De Données
![Buffalo](https://files.manualsbrain.com/attachments/9b1b53b017a12138833f39c4f8c1f2aa34c2c16e/common/fit/150/50/266e1b8b2619927602ffd298e5482e1aaec72f4e72045ee85919e6306019/brand_logo.png)
Codes de produits
LS441D0404-EU
46
Rebuilding the RAID Array from a Computer
Before turning off the LinkStation, determine which hard drive has failed. The failed drive's status LED will be
glowing red.
glowing red.
1
Turn the LinkStation off and remove all cables.
2
Squeeze the left side of the front panel and swing it open.
3
Pull the failed drive's cartridge out of the LinkStation.
Notes:
• Do not press hard on the top of the LinkStation.
• Pull the drive straight out the front of the chassis.
• Do not press hard on the top of the LinkStation.
• Pull the drive straight out the front of the chassis.
4
Remove the drive from the cartridge.