QNAP TS-470U-SP Fiche De Données

Page de 344
54
Error: A disk drive detected with errors (could be bad sectors or I/O errors) and it is
recommended that this disk drive is to be replaced immediately.
Spare: A disk drive configured as spare drive for a RAID group.
Cache: A disk drive configured as cache.
None: A disk drive that has not been configured.
 
Refer to the following table for actions available to manage a disk:
Ac tion
De s c ription
Disk Info
Click this button to check details of a disk, including the model,
model number, serial number, capacity, firmware version, ATA version
and ATA standard.
Disk
Health
Click this button to check disk S.M.A.R.T information. More details
about S.M.A.R.T information will be provided in the next table.
Scan Now
(under
"Action")
Click this button to scan the disk for bad blocks. If bad blocks are
found, the number of bad blocks will be displayed in the "Status"
field. Check the bad block sectors by clicking on the "bad blocks"
message so long as the disk is not busy.
Locate
(under
"Action")
Click this button to beep and blink the LED for easy identification of
physical hard drives.
Set as
Enclosure
Spare
(under
"Action")
Click this button to set or cancel the chosen hard disk drive as an
enclosure spare drive. An enclosure spare drive can be used to
replace a failed hard disk drive in RAID 1, RAID 5, RAID 6, or RAID 10.
In case a spare drive is shared by multiple RAID groups, that spare
drive will be used to replace the first failed drive across all RAID
groups. Please note that the capacity of the enclosure spare drive
must be equal to or larger than that of the member drive in a RAID
group.
RAID
Group
Click this button and select a RAID group and check its details,
including capacity, RAID group name, RAID type and disk member.