Description 
The 
absolute command is used to create an absolute mode time-range for the 
PoE time-range of the switch. The switch will supply power when the specified 
absolute time occurs. To delete the corresponding absolute mode time-range 
configuration, please use 
no absolute command. 
Syntax 
absolute start start-date end end-date 
no absolute 
Parameter 
start-date  ——  The start date in Absoluteness Mode, in the format of 
MM/DD/YYYY. 
end-date  ——  The end date in Absoluteness Mode, in the format of 
MM/DD/YYYY. 
Command Mode 
Power Time-range Create Configuration Mode 
Example 
Create an absolute mode time-range for the PoE of the switch and specify the 
date extending from May 5, 2012 through Oct. 5, 2012: 
TL-SG2424P(config)# power time-range tRange1   
TL-SG2424P(config-pwr-time-range)# absolute start 05/05/2012 end 10/05/2012 
periodic 
Description 
The 
periodic command is used to create a periodic mode time-range for the 
PoE time-range of the switch. The switch will supply power when the specified 
periodic time occurs. To delete the corresponding periodic mode time-range 
configuration, please use 
no periodic command. 
Syntax 
periodic { [ week-date week-day ] [ time-slice1 time-slice ] [ time-slice2 time-slice 
time-slice3 time-slice ] [ time-slice4 time-slice ] } 
no periodic [ week-date | time-slice ] 