Cisco 1 Port T3/E3 Spare PA-T3/E3-EC= Fiche De Données
Codes de produits
PA-T3/E3-EC=
Data Sheet
All contents are Copyright © 1992–2007 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information.
Page 5 of 6
Product Specifications
Table 5.
Product Specifications
Product
Specifications
Physical
●
Dimensions (H x W x D): Approximately 1 x 6 5/8 x 7 inches (2.5 x 16.8 x 17.8 cm) overall
●
Approximate weight: 2.5 lb (1.13 KG)
Environmental
●
Storage temperature: –38 to 150°F (–40 to 70°C)
●
Operating temperature, nominal: 77°F (25°C), ranges 0 to 40°C (32 to 104°F)
●
Storage relative humidity: 5 to 95 percent relative humidity (RH) noncondensing
●
Operating humidity, nominal: 5 to 85 percent RH noncondensing
●
Operating humidity, short-term: 5 to 90 percent RH noncondensing
●
Operating altitude: –60 to 2000 meters
Regulatory
Compliance
Compliance
CE Marking
Safety
●
CFR 47, Part 15 Class A
●
ICES 003 Class A
●
UL 60950-1
●
IEC 60950-1
●
EN 60950-1
●
CAN/CSA-C22.2 No. 60950-1
●
AS/NZS 60950.1
Emissions
Requirements
Requirements
●
CFR 47, Part 15 Class A
●
ICES 003 Class A
●
CISPR 22 Class A
●
EN 55022 Class A
●
EN 300386:2001
●
EN 61000-3-2:2000
●
EN 61000-3-3:2000
●
AS/NZS CISPR 22 Class A
●
VCCI: V-3/2000.04 Class A
Immunity
Requirements
Requirements
●
EN 50082-1
●
EN 55024
●
EN300 386
●
EN61000-6-1
The port adapters meet the following specifications as defined in the reference standards given
previously. The approval levels are those required by each country where the product is marketed,
sold, and used as detailed by the approval levels of the host system and relevant standards.
Investigations will be made against the Cisco quality levels for informational purposes as a
measure of system quality. The quality levels are defined as follows:
previously. The approval levels are those required by each country where the product is marketed,
sold, and used as detailed by the approval levels of the host system and relevant standards.
Investigations will be made against the Cisco quality levels for informational purposes as a
measure of system quality. The quality levels are defined as follows:
●
EN 61000-4-2 ESD 8kV/15kV
●
EN 61000-4-3 Radiated Immunity 10V/m
●
EN 61000-4-4 EFT AC 4kV
●
EN 61000-4-4 EFT DC 4kV
●
EN 61000-4-4 EFT Sign. Line 1kV/2kV
●
EN 61000-4-5 Surge AC L-E 4kV
●
EN 61000-4-5 Surge AC L-L 2kV
●
EN 61000-4-5 Surge DC 1kV
●
EN 61000-4-5 Surge Sign. Line 500 V
●
EN 61000-4-6 RF conducted immunity 10V
●
EN 61000-4-8 Immunity to magnetic fields 30A
●
EN 61000-4-11 Voltage dips and interruptions AC Line