Cliff FC6625 Fiche De Données

Page de 1
APPLICATIONS
:
 Power supply, Amplifier, UPS, Regulator, Generator.
Mounting options - With Nut (U Type), Snap in (W Type)
SPECIFICATION
Rating
4 - 16 Amperes in 1A. steps (13 Models).
Input Power
32VDC / 120VAC / 240VAC
Dielectric strength
1500VAC / 1 min.
Interrupt capacity
@ 120VAC - 1000A., @ 240 VAC - 200A.
Calibration
@ 25°C 105% of rated current - Continuous..
@ 25°C 196% to 134% of rated current - May / May not trip.
@ 25°C 200% of rated current - Trip within 1 minute.
E.g. 4 amp model @ 25°C 150% of rated current - Trip within 60 mins.
Contact endurance
@ 120VAC / 150% of rated current - 500 cycles.
CIRCUIT PROTECTOR
A-070 Series
8
OPTION
NAMEPLATE
WASHER ‘C’
HEX NUT
(‘A’ TYPE)
ROUND NUT
(‘B’ TYPE)
TRIP TIME CURVE
MANUAL
VDE Pending
Max Internal Resistance
4A-5A
0.120
W
5A-6A
0.100
W
6A-7A
0.075
W
7A-8A
0.035
W
8A-9A
0.020
W
10A-13A
0.015
W
14A-15A
0.010
W
15A-16A
0.008
W
Derating Factor
TEMP.
4A.
5A-16A.
10°C
x1.45
x1.20
15°C
x1.20
x1.11
20°C
x1.10
x1.06
25°C
x1.00
x1.00
30°C
x0.80
x0.93
35°C
x0.65
x0.88
40°C
x0.50
x0.83
45°C
-
x0.77
50°C
-
x0.72
55°C
-
x0.65
60°C
-
x0.58
Reset button may be black or red
.