<Functions of Linkage Menu>
Telemetry function (FASSTest mode only)
To use the telemetry function, set “Telemetry” 
to “ACT”.
DL Interval (FASSTest mode only)
When a telemetry function is enabled, the 
receiving interval (down-link interval) of sensor 
data can be changed. 
If a DL interval is increased, the  response of 
the sensor data display becomes slower, but stick 
response will improve. 
System Type selection procedure
1. Move  the  cursor  to  the  [FASSTest-14CH] 
item and touch the RTN button to switch to 
the data input mode. 
2. Select  the  system  type  by  scrolling  the 
touch sensor.
  [FASSTest-14CH][FASSTest-12CH][FASST-
MULT][FASST-7CH][S-FHSS]
*An example of selections for each system is on the 
following page.
3. Touch the RTN button to end adjustment 
and return to the cursor mode.
Dual receiver function (only FASSTest 14CH 
mode) procedure
1. Move the cursor to the [SINGLE] item and 
touch the RTN button to switch to the data 
input mode. 
2. Select the [SINGLE] or [DUAL] by scrolling 
the touch sensor.
3. Touch the RTN button to end adjustment and 
return to the cursor mode.
Area mode selection (Frequency range)
procedure
1. Move the cursor to the [G] item and touch 
the RTN button to switch to the data input 
mode. 
2. Select  the  [G]or[F]  by  scrolling  the  touch 
sensor.
*"F" is chosen only when using the transmitter is used in 
France. Leave this in "G" otherwise.
3. Touch the RTN button to end adjustment and 
return to the cursor mode.
Telemetry ACT/INH procedure
1. Move the cursor to the TELEMETRY [ACT] item 
and touch the RTN button to switch to the 
data input mode. 
2. Select the [ACT]or[INH] by scrolling the touch 
sensor.
3. Touch the RTN button to end adjustment and 
return to the cursor mode.
DL Interval set procedure
1. Move the cursor to the TELEMETRY DL[1.0s] 
item and touch the RTN button to switch to 
the data input mode. 
2. Select  the  DL  time  by  scrolling  the  touch 
sensor.  If  a  DL  interval  is  increased,  the  
response of the sensor data display becomes 
slower, but stick response will improve.
  Initial value: 1.0s
  Adjustment range : 0.1s~2.0s
3. Touch the RTN button to end adjustment and 
return to the cursor mode.
ID  of  a  Primary 
receiver displays.
ID of a Secondary 
receiver displays.
In DUAL, a primary receiver 
is  link  previously.  Next,  a 
secondary receiver is link.