Panasonic LC-R121R3PG 16010 Fiche De Données
Codes de produits
16010
30
Valve Regulated Lead-Acid Batteries
31
Valve Regulated Lead-Acid Batteries
10 | Battery Selection Guide
Steps for selecting batteries are described below.
Study of required specifications (draft)
Study the required specifications (draft) by checking the
requirements for the battery with the battery selection
criteria. Technical requirements for selecting the battery are
presented below.
Battery selection
First, select several candidate batteries by referring to
the technical brochures and data sheets of the batteries
presently available. Then from the candidates select a
battery which can meet as many of the ideal requirements
as possible. In fact, however, battery selection can be
seldom made so smoothly. Practically, possible removal or
easing of the requirements should be considered first; then
depending on the result, a proper battery should be selected
from those presently available. This way of proceeding
enables economic selection of the battery. Any questions
at this stage should be asked to battery engineers in depth.
Sometimes, new or improved batteries which are not carried
in the brochures have become available, and an appropriate
battery may be found among them. Usually, required
specifications are finalized at this stage.
Request for improving or developing batteries
If no battery which will satisfy special requirements can
be found by the above-described approach, requests for
improving or developing new batteries should be made to
our technical department, and these requests should be
coordinated as quickly as possible to allow enough time for
studying: the study takes usually 6 to 12 months or even
longer depending on the request. In this section, guidelines
for selecting appropriate batteries for specific equipment
were mentioned. If further information regarding the battery
selection is required, please contact us.
Technical requirements for battery selection
Electrical requirement
Charge condition
Temperature and
humidity
humidity
Dimensions, mass
and shape
and shape
Others
Life
Ambient temperature
and humidity
and humidity
˚C max.
˚C min.
% max.
% min.
Storage temperature
and humidity
and humidity
˚C max.
˚C min.
% max.
% min.
Height (mm)
Length (mm)
Width (mm)
Mass (g)
Terminal shape
max.
max.
max.
av.
Atmosphere pressure
Mechanical condition
Safety
Mechanical condition
Safety
Inter-changeability
Marketability
Price
Marketability
Price
Cycle life
Trickle life
Storage period
years
cycles
Battery selection
Cycle charge
Trickle/Float
charge
Charging time
Charging temperature
Atmosphere
Atmosphere
˚C max.
˚C min.
Voltage range
Vmax.
Vmin.
Continuous load
mA(max.)
mA(av.)
mA(min.)
Intermittent load
(Pulse load)
mA(max.)
mA(av.)
mA(min.)
ON/OFF condition
ON time
ON time
OFF time
*
1
This battery is also available with a flame retardant battery case resin (UL94 V-0).
*
2
LC-R127R2P is available with flame retardant case resin (UL94 V-0) but with no VdS certification.
LC Series – Trickle Design Life 6 – 9 Years
Model Number
Nominal
Voltage
(V)
Rated Capacity (Ah)
Dimensions (mm)
Mass
approx.
(kg)
Page
VdS N°
20 hour rate
Length
Width
Height
Approx.
Total Height
LC-R061R3P
*
1
6
1.3
97
24
50
55
0.3
36
–
LC-R063R4P
*
1
6
3.4
134
34
60
66
0.6
38
–
LC-R064R5P
*
1
6
4.5
70
48
102
108
0.7
40
–
LC-R067R2P
*
1
6
7.2
151
34
94
100
1.3
42
–
LC-R0612P
*
1
6
12
151
50
94
100
2.0
44
–
LC-R0615P
6
15
151
50
94
100
2.1
46
–
LC-R121R3PG
12
1.3
97
47.5
50
55
0.6
48
G196049
LC-R122R2PG
12
2.2
177
34
60
66
0.8
50
G188151
LC-R123R4PG
12
3.4
134
67
60
66
1.2
52
G191053
LC-R124R5P
12
4.5
70
97
102
108
1.5
54
–
LC-R127R2PG
*
2
12
7.2
151
64.5
94
100
2.5
56
G193046
LC-RA1212PG
12
12
151
98
94
100
3.8
58
G100001
LC-RA1215P
12
15
151
98
94
100
4.2
60
–
LC-R1233P
12
33
195.6
130
155
180
12.0
62
–
LC-V1233P
12
33
195.6
130
155
180
11.1
64
–
VdS
LC Series – Trickle Design Life 10 – 12 Years
Model Number
Nominal
Voltage
(V)
Rated Capacity (Ah)
Dimensions (mm)
Mass
approx.
(kg)
Page
VdS N°
20 hour rate
Length
Width
Height
Approx.
Total Height
LC-P067R2P
6
7.2
151
34
94
100
1.30
66
–
LC-P0612P
6
12
151
50
94
100
2.00
68
–
LC-X06200P
*
1
6
200
407
173
210
250
41.00
70
–
LC-P122R2P
12
2.2
177
34
60
66
0.80
72
–
LC-P123R4P
12
3.4
134
67
60
66
1.20
74
–
LC-P127R2P
12
7.2
151
64,5
94
100
2.50
76
–
LC-PA1212P
12
12
151
98
94
100
3.80
78
–
LC-XD1217PG/APG
12
17
181
76
167
167
6.50
80
G104101
VdS
11 | Battery Index
Battery Types and Model Numbers
Application
Series
Trickle Design
Life (at 20°C)
Category
Standard ABS
(UL94 HB)
FR ABS = Flame Retardant
ABS (UL94 V-0)
Back Up
LC-V
6 – 9 years
Trickle standard type
LC-X
10 – 12 years
Trickle long life type
LC-P
10 – 12 years
Trickle long life type
LC-QA
15 years
Trickle super long life type
UP-RW
6 – 9 years
High power standard type
UP-PW
10 – 12 years
High power long life type
Back Up and Main Power
LC-R
6 – 9 years
Trickle and cycle standard type
Main Power
LC-CA
-
Cycle long life type
LC-XC
-
Cycle long life type