Easy to communicate between devices 
 
7.10 PtP, USS, and Modbus communication protocols 
Easy Book 
Manual, 03/2014, A5E02486774-AF 
167
 
7.10.5 
Modbus instructions 
The CPU supports Modbus communication over different networks: 
●  Modbus RTU (Remote Terminal Unit) is a standard network communication protocol that 
uses the RS232 or RS485 electrical connection for serial data transfer between Modbus 
network devices. You can add PtP (Point to Point) network ports to a CPU with a RS232 
or RS485 CM or a RS485 CB. 
Modbus RTU uses a master/slave network where all communications are initiated by a 
single Master device and slaves can only respond to a master’s request. The master 
sends a request to one slave address and only that slave address responds to the 
command. 
●  Modbus TCP (Transmission Control Protocol) is a standard network communication 
protocol that uses the PROFINET connector on the CPU for TCP/IP communication. No 
additional communication hardware module is required. 
Modbus TCP uses client-server connections as a Modbus communication path. Multiple 
client-server connections may exist, in addition to the connection between STEP 7 and 
the CPU. Mixed client and server connections are supported up to the maximum number 
of connections allowed by the CPU. Each MB_SERVER connection must use a unique 
instance DB and IP port number. Only 1 connection per IP port is supported. Each 
MB_SERVER (with its unique instance DB and IP port) must be executed individually for 
each connection. 
 
 
 
WARNING 
If an attacker can physically access your networks, the attacker can possibly read and 
write data. 
The TIA Portal, the CPU, and HMIs (except HMIs using GET/PUT) use secure 
communication that protects against replay and "man-in-the-middle" attacks. Once 
communication is enabled, the exchange of signed messages takes place in clear text 
which allows an attacker to read data, but protects against unauthorized writing of data. 
The TIA Portal, not the communication process, encrypts the data of know-how 
protected blocks. 
All other forms of communication (I/O exchange through PROFIBUS, PROFINET, AS-i, 
or other I/O bus, GET/PUT, T-Block, and communication modules (CM)) have no 
security features. You must protect these forms of communication by limiting physical 
access. If an attacker can physically access your networks utilizing these forms of 
communication, the attacker can possibly read and write data. 
For security information and recommendations, please see our "Operational Guidelines 
for Industrial Security" on the Service and Support site: 
www.industry.siemens.com/topics/global/en/industrial-
security/Documents/operational_guidelines_industrial_security_en.pdf 
) 
 
 
 
Note 
Modbus TCP will only operate correctly with CPU firmware release V1.02 or later. An 
attempt to execute the Modbus instructions on an earlier firmware version will result in an 
error.