Elro HA68S Fiche De Données

Page de 34
-51-
-14-
SETTING THE PIR DETECTORS
Located on the PCB of the PIR Detector is a two-position DIP switch (SW2). 
When conducting the Walk Test, ensure that the DIP switch SW2 is set as 
follows:
1. DIP1 of SW2 is used to configure the PIR Detector for walk test mode, which 
allows the operation of the detector to be checked during installation without 
triggering a Full Alarm.
ON
Walk Test mode
OFF Normal mode
Note: On initial installation the detector should be set into Walk Test mode 
ready for testing. Upon completion of Walk Test mode, set DIP1 of SW2 to 
OFF for normal detection mode.
2. The PIR Detector incorporates an anti-false alarm feature designed to 
compensate for situations where the detector may be affected by 
environmental changes, (e.g. insects, air temperature, etc). This feature is 
called “sensitivity detection” and may be selected for high or low detection.
The recommended setting is for high sensitivity detection. However, in cases 
of extreme environmental problems or if unattributable false alarms are 
experienced, it may be necessary to select low sensitivity detection.
Set the required sensitivity detection using DIP2 of SW2 as follows:
ON
high sensitivity detection
OFF low sensitivity detection
Note: The higher the sensitivity detection the less movement will be 
necessary before the PIR detector will trigger the alarm.
SW2
DIP1
DIP2
ON
OFF
DIP-switch
(SW2)
EXIT DELAY
Scroll through the menu until ‘7-1 Exit Delay’ is displayed. The current setting 
will also be displayed.
Default setting: ON, 30s
To change the setting press       .
Press        to enable the Exit delay and enter the required exit delay period 
(1-250s), or
Press        to disable the Exit delay.
Press        to save and exit, or 
Press        to exit without saving.
ENTRY DELAY BEEP
This controls the warning beep which operates during the Entry Delay period 
when Partial Arm 2 is active.
Default setting: ON
Scroll through the menu until ‘:7-2 Entry Delay Beep’ is displayed. The current 
setting will also be displayed.
To change the setting press        .
Press        to enable the Entry-delay beep, or
Press        to disable the Entry-delay beep.
 
 
PROGRAM MODE
Code
7. PARTIAL
ARM2
7-1 Exit Delay
xx xxx SEC
Select
ON->*  OFF->#
Select
ON->*  OFF->#
Input (1-250) Secs
7-2 Entry Delay 
Beep: xxx
7-3 Exit Delay
Beep: xxx
EN
EN
Select 
ON->  OFF->#