In addition there is the facility to connect 4 hard wired zones to the Control 
Panel, each of which is fully configurable with the same features as the wirefree 
zones (1-32).
ENTRY/EXIT DELAY
When the system is armed with the Exit-Delay enabled, no alarm signal from 
any detector on an active zone will be able to initiate an alarm until the Exit-
Delay has expired. This enables the system to be armed from within the 
property and allows time for the user to exit the property without triggering an 
alarm. If the Exit-Delay is disabled then detectors on active zones will 
immediately be able to initiate an alarm as soon as the system begins to arm.
The system Exit-Delay may be configured for between 10 to 250 seconds or 
disabled completely.
If a detector on a zone with its Entry-Delay enabled is triggered, then an alarm 
condition will not occur until the Entry-Delay period has expired. This allows time 
for the user to re-enter the property and disarm the system before an alarm 
condition occurs. Generally only the zones on the main entry route to the 
property will be configured with an Entry-Delay. The remaining zones would be 
configured with their Entry-Delay disabled allowing them to immediately initiate 
an alarm a detector on the zone is triggered.
The Entry-Delay for each zone may be configured for between 10 to 250 
seconds or disabled completely.
QUICK SET
The system may be fully armed in 5 seconds using the quick set facility, 
overriding the programmed exit-delay.
This is useful for setting the system at night when the exit-delay warning beep 
will be silenced after just a few seconds.
ZONE LOCKOUT
If a detector on an active zone is triggered while the system is armed an alarm 
condition will occur. After the programmed alarm duration has expired the alarm
will stop. If a single zone initiates an alarm
condition more than three times then that zone will be ‘Locked Out’ and any 
further alarm signals from that zone will be ignored until the system is 
disarmed.
Note: The ‘Zone Lockout’ feature can be disabled if required.
EVENT LOG
The Control Panel incorporates a memory capable of storing the last 50 system 
events. This enables the user to see which user has Armed/Disarmed the system 
and if and when any alarms occurred. The time, date and details of the event 
type will be recorded for each system event.
BATTERIES
Before removing the battery cover on any device to replace the battery, ensure 
that the system is put into Test mode to avoid initiating an Alarm.
The specifications for replacement batteries are as follows:
Note: Rechargeable batteries should NOT be fitted.
At the end of their useful life the batteries should be disposed of via a suitable 
Recycling Centre.  Do not dispose of with your normal household waste.  DO 
NOT BURN.
The Rechargeable batteries contain Sulphuric Acid – DO NOT ATTEMPT TO OPEN 
THE CASING.