Renesas YR0K77210S003BE Fiche De Données

Page de 58
RSK+RZA1H  
8. 
Code 
Development 
R20UT2587EG0200 Rev. 2.00 
 
Page 52 of 58 
Mar 21, 2014 
 
8.9 
Dual QSPI Debugger (Programming) Settings  
 
Additional steps are required for connecting to the RSK+RZA1H with a DS-5 project configured to run from 
QSPI. The following steps assume the user has gone through the RSK+RZA1H’s Quick Start Guide. 
 
These steps also assume that the User Boot Loader is still resident on your board. If you have re-programmed 
the Channel 0 Port 0 QSPI flash device, this loader may not be resident. In this case we provide the source 
project for the User Boot Loader in the sample set, and a simple batch file to re-flash the User Boot Loader. 
Please refer to the description.txt file in this project for details. 
 
Append the following string to the debugger’s serial number in the debug configurations settings of the DS-5 
user application sample project “:device R7S721001_DualSPI”, without the quote marks.  
 
Note: This must not be used when using the User Boot Loader Program sample project in DS-5. 
 
To open the debug configurations settings in DS-5, click on the small triangle to the right of the Debug icon 
and select Debug Configurations… from the menu bar as shown below. 
 
 
 
Expand the DS-5 Debugger entry to reveal the debug configuration as shown in the following example. 
 
 
 
Click on the desired configuration; e.g. RZA1_Debug, to open the Files tabs. Under the Connection tab, 
append the string to the detected J-Link debugger’s serial number (highlighted in the example below).