Bosch Appliances Home Security System D1260B Manuel D’Utilisation

Page de 100
D1260/D1260B | Owner's Manual | Part IV: Multi-Area Use - Turn On the Entire System Without Delays 
 
 
72 
Bosch Security Systems | 9/04 | 50410D 
 
1.
 
Enter your passcode and press 
ENTER. 
 
2.
 
The command center will display the following: 
 
Command center scope and/or your authority 
level limit the actual number of areas you may 
turn on. For example, if you have authority to arm 
all 8 areas but the scope of the command center 
you’re using is limited to areas 1, 2, and 5, then 
you will only be able to turn on areas 1, 2, and 5. 
3.
 
If a point is faulted (door or window open for 
example), see Turning On the System (Arming) With 
Doors or Windows Open
 for further information. 
Faulted Points in Other Areas 
If there is a faulted point in an area you select (other 
than the one you are in), 
Check Area 1 
(1 is used as 
an example here) appears for 3 seconds and then the 
display returns to the area disarmed idle text. 
 
If there is a faulted point in more than one area and the 
system is being armed, the display will prompt 
Check 
Area 1 3
 meaning there are faulted points in Areas 1 
and 3. 
 
Try one of the following: 
 
Clear faulted points (close doors and/or windows) 
and return to step 1. 
 
Bypass faulted points (if your system and/or 
authority allows) and return to step 1. 
 
Force arm (if your system and/or authority allows). 
See Turning On the System (Arming) With Doors or 
Windows Open
 for more information. 
Turn On the Entire System Without Delays 
You can use this Command Menu function to turn on 
the entire system, both perimeter and interior, without 
delays. You may use this function in all of the areas or 
some of the areas where your passcode has authority. If 
there are areas already turned on, this function turns on 
all areas that are off without changing the status of the 
areas that are already on. 
Turning on All or Selected Areas 
Areas covered in the scope of the command center can 
be armed individually by accessing the Master Arm 
function through the menu. 
1.
 
Press the 
Menu>
 key to enter the Command 
Menu. 
 
2.
 
Press the 
Next>
 soft key repeatedly until you 
reach the 
MASTER ARM INST ?>
 prompt then 
press the adjacent soft key. 
 
 
3.
 
You will prompted for your passcode. It will 
appear on the display as asterisks (*). 
 
4.
 
The display changes and shows 
MASTER ARM 
ALL ?
 with the following options: 
 
<Previous
 soft key – will scroll to the last area 
that can be armed (based on passcode and 
authority level) 
 
Next> 
soft key – will scroll to the first area 
that can be armed (based on passcode and 
authority level) 
 
Arm> 
 soft key – will arm all areas (based on 
passcode and authority level) 
 
<Exit
 soft key – will return the display to idle 
text