Galil DMC-2X00 Manuel D’Utilisation

Page de 267
18  
 Chapter 2  Getting Started 
DMC-2X00  
Switch 4,5 and 6 - Main Serial Port Baud Rate 
The following table describes the baud rate settings: 
 
9600 19.2 3800  BAUD 
RATE 
ON ON OFF 
1200 
ON OFF OFF 
9600 
OFF ON OFF 
19200 
OFF OFF ON 
38400 
OFF ON ON 
115200 
Switch 7-Option 
When OFF, the controller will use the auto-negotiate function to set the Ethernet connection speed.  
When the DIP switch is ON, the controller defaults to 10BaseT. 
Switch 8-Ethernet 
When ON, the controller will use the Ethernet port as the default port for unsolicited messages.  When 
OFF, the controller will use the RS-232 port as the default.  When the firmware is updated, the 
controller will send the response (a colon) to the default port setting.  If this is not the same port that 
was used to download the firmware, the Galil software will not return control to the user.   In this case, 
the software will have to be re-started. 
Step 4. Install the Communications Software 
After applying power to the computer, you should install the Galil software that enables 
communication between the controller and PC.   
Using Windows 98SE, NT, ME, 2000 or XP: 
The Galil Software CD-ROM will automatically begin the installation procedure when the CD-ROM is 
installed.  To install the basic communications software, run the Galil Software CD-ROM and choose 
DMC Smart Term.  This will install the Galil Smart Terminal, which can be used for communication. 
Step 5. Connect AC Power to the Controller 
Before applying power, connect the 100-pin cable between the DMC-2x00 and ICM-2900 interconnect 
module. The DMC-2x00 requires a single AC supply voltage, single phase, 50 Hz or 60 Hz. from 90 
volts to 260 volts. 
 
WARNING:  Dangerous voltages, current, temperatures and energy levels exist in this product and 
the associated amplifiers and servo motor(s).  Extreme caution should be exercised in the 
application of this equipment.  Only qualified individuals should attempt to install, set up and 
operate this equipment.  Never open the controller box when AC power is applied to it. 
The green power light indicator should go on when power is applied.