Apollo SA-02-015 Manuel D’Utilisation

Page de 16
 
User Manual
DI170S01-A01
 
 
 
DI170S01-A01 
Product No. : SA-02-015 
 
 
Rev 1 
May 23, 2005 
Page 4 of 16 
 
4  Absolute Ratings of Environment 
 
Item 
Symbol 
Min. 
Max. 
Unit 
Note 
Storage temparature 
T
STG
 -25  60 
°C (1) 
Operating temparature    
(Glass surface temperature) 
T
OPR
 0  50 
°C (1) 
Shock (non-operating) 
Snop 
50 
(2), (4) 
Vibration (non-operating) 
Vnop 
1.5 
(3), (4) 
 
Note 
(1)   Temperature and relative humidity range are shown in the figure below. 
 
90 % RH Max. (40 
°C 
≥ Ta) 
 
Maximum wet-bulb temperature at 39 
°C or less. (Ta > 40 °C) No condensation.  
(2)   11 ms, sine wave, one time for 
±X, ±Y, ±Z axis 
(3)   10-300 Hz, Sweep rate 10 min, 30 min for X, Y, Z axis 
(4)   At vibration and shock test, the fixture which holds the module to be tested has to be hard and rigid enough so 
that the module would not be twisted or bent by the fixture.