Connect positive DC line to the ‘+24V’ terminal and the DC ground 
to the ‘GND‘ terminal. 
FUSE Replacement: 
The fuse use on MT608 is: 
BUSSMANN 
Fast Acting, Glass Tube 
Rating: 250VAC, 1A 
Size: 5x20mm 
Warning: 
1.
 
Make sure the power off before replace 
the fuse. 
2.
 
Do not replace the fuse with a different 
rating fuse. 
 
2.2.2 Grounding Requirements 
 
Chassis ground must be used. DC ground is not directly coupled to Earth ground internally. It 
is preferable not to ground DC negative return to chassis ground as poor site earths can introduce 
noise into a system, but if necessary an earth connection should be made, from the power supply 
return point to the central star earth point. Ground conductors should be as short and as large in 
size as possible. The conductors must always be large enough to carry the maximum short circuit 
current of the path being considered. Ground conductors should be connected to a tree from a 
central star earth ground point. This ensures that no ground conductor carries current from any 
other branch. 
 
 
 
2.2.3 CE Requirements 
To make an NP-610X comply with EMC directives, and to reduce susceptibility to electrical 
interference, a separate #14 AWG ground wire should be taken to the chassis ground terminal of 
the power connector. This ground connection should be run directly to the central star earth 
connection point (as recommended in most Installation Instructions).