Vixel Switch 335 Manuel D’Utilisation

Page de 74
Vixel Model 335 Installation & Configuration Guide
CHAPTER 3 
Management
22
RRDY
The receiving node on this port has sent an R_RDY signal, 
indicating that it is ready for a frame to be transmitted over the 
link.
CLS
The port is attempting to begin the process of closing the current 
loop circuit.
OPN
The port is attempting to open communications with another 
port on the loop. Note: As is the case with some ordered sets, an 
OPN may not go all the way around the loop, instead stopping 
at its destination. 
LIP F8
A non-switching port has detected a loop failure on its receive 
input, is notifying other ports, and is determining whether the 
loop is still operational. 
Some events that could cause the port to detect loop failure 
follow:
• A device in the loop has failed.
• A device in the loop has been powered off.
• The physical connection between the transmitter and receiver 
is broken.
• Activating the port bypass circuit does not typically result in a 
loop failure. 
LIP F7
A loop port is in the non-participating mode and is attempting 
to win arbitration and begin initialization, possibly because the 
port was reset or is powering up. Sometimes the port is sending 
this sequence to another, hot-cascaded switch like a new initiator 
being inserted in the loop.
LIP 
A Loop Initialization Primitive (LIP) sequence has been detected 
and action has been taken. 
Unknown
The switch can not determine what is being transmitted.
InvTxWd
An invalid transmit word has been detected.
CRC Err
A Frame CRC error has been detected.
Pt-to-Pt
A point-to-point connection has been detected.