Multiquip Pet Fence mtr-40hs Manuel D’Utilisation

Page de 66
PAGE 16 — MTR-40HS— PARTS & OPERATION MANUAL — REV. #2 (12/15/03)
MTR-40HS— INITIAL START-UP
Figure 6. Fuel Shut-Off Valve (Open)
2.
Set  the engine ON/OFF switch (Figure 7) to the "ON"
position (start).
Figure 7. ON/OFF Switch (ON Position)
3. Move the throttle lever to the "IDLE" position (Figure 8).
Figure 9. Choke Lever (Closed)
Figure 8. Throttle Lever (Idle)
4. In cold weather, start the unit with choke lever "Fully Closed"
(Figure 9).  In warm weather or when the engine is warm, the
unit can be started with choke halfway or completely open.
This section is intended to assist the
operator with the 
initial start-up of the
MTR-40HS rammer. It is extremely
important that this section be 
read
carefully before attempting to use the
rammer in the field.
DO NOT use your rammer until this section is thoroughly
understood.
CAUTION:
Failure to understand the
 initial start-up
procedures of the MTR-40HS rammer could
result in severe damage to the rammer or
personal injury.
See Figure 1 (Page 13) for the location of any control referenced
in this manual.
Initial Start-up
The following steps outline the procedure for starting the engine:
1.
Open the  
fuel shut- off valve by moving the fuel  cock
lever to the 
open position (Figure 6).