White Rodgers 24A06G-1 Level Temp Silent Operator For Low Voltage Control Of Electric Heat Manuel De Montage

Page de 8
24A06G-1
DUAL LEVEL-TEMP 
SILENT OPERATOR RELAY 
(Normally Open Contacts)
INSTALLATION INSTRUCTIONS
Operator:  Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE 
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL 
INJURY AND/OR PROPERTY DAMAGE.
 
 PRECAUTIONS
This Dual Level-Temp Silent Operator Relay is designed for con-
trolling two separate loads with a single low voltage thermostat. 
It is especially suitable for use with electric heating equipment.
The Dual Level-Temp relay may be used to operate two separate 
heating loads by means of a single low voltage thermostat. It 
is equally well suited for use with a heating-cooling thermostat 
to control heating and cooling loads alternately as in motels, 
apartments, office buildings, etc.
This model Dual Level-Temp relay has a voltage input of 240  
volts. Since this relay is equipped with a self-contained trans-
former, the supply voltage used must agree with the voltage 
rating of the relay. This model has both an inductive and non-
inductive rating.
If in doubt about whether your wiring is millivolt, line, or low 
voltage, have it inspected by a qualified heating and air con-
ditioning contractor, electrician, or someone familiar with basic 
electricity and wiring.
Do not exceed the specification ratings.
All wiring must conform to local and national electrical codes 
and ordinances.
This control is a precision instrument, and should be handled 
carefully.  Rough handling or distorting components could cause 
the control to malfunction.
 
 
DESCRIPTION
 
 SPECIFICATIONS
ELECTRICAL DATA 
Switch Action: Two SPST switches, normally open 
Thermal: Average time delay – 45 seconds 
Ambient Temperature: -20° to 120°F (-24° to 49°C) 
Mounting: 1/2" conduit hub or two key slot mounting holes
Thermostat Circuit Current: 
  Bimetal Heater #1 (Red & White Leads) – 0.21 Amps 
 
Bimetal Heater #2 (Red & Black with White Stripe 
 Leads) – 0.21 Amps
The Silent Operator relay has been carefully adjusted at the fac-
tory, and no attempt should be made to adjust them in the field.
CAUTION
!
To prevent electrical shock and/or equipment damage, 
disconnect electric power to system at main fuse or 
circuit breaker box until installation is complete.
WARNING
!
Do not use on circuits exceeding specified voltage.  
Higher voltage will damage control and could cause 
shock or fire hazard.
PART NO. 37-4165D
Replaces 37-4165C
1236
www.white-rodgers.com
www.emersonclimate.com
TYPE
NUMBER
INPUT
vOLTAGE /FREqUENCY
ELECTRICAL RATING
FOR SWITCH #1
(Red and Black Leads)
FOR SWITCH #2
(Red Striped and Black Striped Leads)
NON-INDUCTIvE
 INDUCTIvE*
 NON-INDUCTIvE
 INDUCTIvE*
24A06G-1
240VAC, 60 Hz
25A, 6000W
12 FLA (72 LRA)
25A, 6000W
12 FLA (72 LRA)
*FLA - Full Load Amps.; LRA - Locked Rotor Amps.