White Rodgers 1F95-1291 Emerson Blue 12" Humidity Touchscreen Programmable Thermostat Manuel De Montage

Page de 16
3
 
 WIRING DIAGRAMS
Figure 2 – Single Stage or Multi-Stage System
(No Heat Pump) with Single Transformer
Single Stage 1
(SS1)
Multi Stage 2
(MS2)
System
RC
RH
C
Y
Y2
W/E
W2
G
O/B
6
L
CLASS II
TRANSFORMER
HOT
24VAC
NEUTRAL
120VAC
Call for heat
Heat mode-1st
stage
Heat mode-2nd
stage
No output
24 volt 
power for 
cooling
24 volt 
power for 
heating
Cool mode-2nd
stage
24 volt 
common 
(optional 
for system 
operation, 
required 
for remote 
sensor)
Call for cool
No Output
Cool mode-1st
stage
Blower/Circulator fan
energized on a call 
for cool or Fan On
(also energized in
heating if configured
for Electric Heat)
Installer
Configuration
Menu selects 
“O” or “B” for 
changeover
function. Set 
to “O” terminal
energized in Cool
& Off mode. Set 
to “B” terminal
energized in 
Heat & mergency 
mode
Power closed
connection for
SPDT 3-wire
zone valve
Fault or System
Malfunction
Indicator for 
Heat Pumps
with “L” terminal
connection.
Original production 
1F95-1291’s 
do not have this 
connection
Figure 3 – Heat Pump Systems
Heat Pump Connections
If you do not have a heat pump system, refer to figures 3 & 4.
Refer to equipment manufacturers’ instructions for specific system 
wiring information.
You can configure the thermostat for use with the following heat pump 
systems.
Single Stage and Multi-Stage Connections
Refer to equipment manufacturers’ instructions for specific system 
wiring information.
This thermostat is designed to operate a single-transformer or two-
transformer system.
You can configure the thermostat for use with the following fossil fuel 
systems:
Heat
Pump 1
(HP1)
Heat 
Pump 2
(HP2)
System
RC
RH
C
Y
Y2
*W/E
*W2
G
O/B
6
L
CLASS II
TRANSFORMER
HOT
24VAC
NEUTRAL
120VAC
Heat mode-2nd
stage, Emergency
Mode-1st stage
*Note: Dual Fuel
option de-
energizes Heat
mode stage 1
(compressor)
when auxiliary
heat is energized
Heat mode-3rd
stage, Emergency
Mode-1st stage
*Note: Dual Fuel
option de-
energizes Heat
mode stages 1 
and 2 (both
compressors)
when auxiliary
heat is energized
Heat mode-4th
stage, Emergency
Mode-2nd stage
*Note: Dual Fuel
option de-
energizes Heat
mode stages 1 
and 2 (both
compressors)
when auxiliary
heat is energized
Heat mode-3rd
stage, Emergency
Mode-2nd stage
*Note: Dual Fuel
option de-
energizes Heat
mode stage 1
(compressor)
when auxiliary
heat is energized
24 volt 
power for 
cooling
24 volt 
power for 
heating
Heat mode-2nd 
stage, 
Cool mode-2nd 
stage, 
(Compressor)
No Output
24 volt 
common 
(optional 
for system 
operation, 
required 
for remote 
sensor)
Heat mode-1st
stage,
Cool mode-1st
stage,
(Compressor)
Blower/Circulator fan
energized on a call 
for cool or Fan On
(also energized in
heating if configured
for Electric Heat)
Installer
Configuration
Menu selects 
“O” or “B” for 
changeover
function. Set 
to “O” terminal
energized in Cool
& Off mode. Set 
to “B” terminal
energized in 
Heat & mergency 
mode
Power closed
connection for
SPDT 3-wire
zone valve
Fault or System
Malfunction
Indicator for 
Heat Pumps
with “L” terminal
connection.
Original production 
1F95-1291’s 
do not have this 
connection
COOLING
CLASS II
TRANSFORMER
HOT
24VAC
NEUTRAL
120VAC
HEATING
120VAC
*Dual fuel option, if selected turns off compressor(s) when Auxiliary stages energize.
SINGLE STAGE (SS 1)
 gas, oil or electric.
MULTI-STAGE (MS 2) 
gas, oil or electric.
After wiring, see INSTALLER CONFIGURATION section for proper 
thermostat configuration.
HEAT PUMP TYPE 1 (HP 1)
.
 Single stage compressor system; 
gas or electric backup. 
HEAT PUMP TYPE 2 (HP 2). 
Multi-stage compressor or two 
compressor system with gas or electric backup.
After wiring, see INSTALLER CONFIGURATION section for proper 
thermostat configuration.