Hobart FP150 Manuel D’Utilisation

Page de 8
– 7 –
MAINTENANCE
WARNING:  TURN THE MACHINE OFF AND UNPLUG THE ELECTRICAL CORD BEFORE DOING ANY
MAINTENANCE.
Routinely inspect the machine to ensure that it is in proper working order.  Plates must be clean, intact and sharp.
Regularly lubricate the pusher plate shaft with a drop of mineral oil, NOT COOKING OIL.
If the machine develops any problems, contact your local Hobart service office.
REPLACEMENT DICING GRIDS
Depending on usage, dicing grids become dull from wear with an average life expectancy from 8-18 months.
Dicing grids cannot be resharpened and are therefore expendable.  Replacement dicing grids are available from
your local Hobart Service Office.
SERVICE
Contact your local Hobart Service Office for any repairs or adjustments needed on this equipment.  Long-term
service contracts are available on this and other Hobart products.
  9. Replace the locking screw.
10. Place the feed hopper on the hinge pins and lower to normal position.  Turn and lower the pusher plate.
Replace the feed tube pusher.