8. Connect the green (or yellow/green) ground wire to the 
green/yellow ground wire (H) in the terminal box using UL 
listed wire connectors.
9. Reinstall the in-line blower terminal box cover and screw.
10. Reinstall the front cover of the in-line blower housing and 
secure it with 10 mounting screws.
Electrical Connection Inside Range Hood Between In-line 
Blower System and Range Hood
1. With the range hood mounted (see the range hood installation 
instructions), locate the wiring cable connector inside the 
range hood.
2. Connect the 6-wire connector assembly supplied with the 
in-line blower motor system to the mating cable connector 
from the range hood. 
3. Locate the terminal box inside the range hood and install a 
¹⁄₂" (1.3 cm) UL listed or CSA approved strain relief (see the 
range hood installation instructions). 
4. Run the wire ends from the 6-wire connector assembly 
through the 
¹⁄₂" (1.3 cm) strain relief, leaving enough wire 
length to make the wiring connections. Tighten the strain 
relief screws.
5. Connect the wires from the 6-wire connector assembly to the 
wires from the wiring conduit inside the range hood terminal 
box. 
6. Connect the same color wires to each other (black to black, 
white to white, etc.) using UL listed wire connectors.
NOTE: Connect the green (or green/yellow) ground wire from 
the wiring conduit to the green (or bare) ground wire from the 
home power supply using UL listed wire connectors (see the 
“Make Electrical Power Supply Connections to Range Hood” 
section in the range hood installation instructions).
7. Connect the home power supply wiring to the range hood 
following the instructions that are supplied with the range 
hood.  
8. Reinstall the range hood terminal box cover.
9. Reconnect power.  
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire 
in terminal box.
Failure to do so can result in death or electrical shock.
A. UL listed or CSA approved 
¹⁄₂
" wiring conduit
B. UL listed wire connectors
C. Black wires
D. White wires
E. Red wires
F. Blue wires
G. Gray wires
H. Green (or green/yellow) 
wire
I. 6-wire connector assembly
A
B
C
D
E
F
G
H
I