Westinghouse EPA (49 state) and CARB (50 state) WH3250C Manuel Du Propriétaire
33
MAINTENANCE
8. Install the spark plug by carefully following the steps
outlined below:
a - Carefully insert the spark plug back into the
a - Carefully insert the spark plug back into the
cylinder head. Hand-thread the spark plug until
it bottoms out.
b - Using the 13/16" spark plug socket wrench
provided, turn the spark plug to ensure it is fully
seated.
c - Replace the spark plug boot, making sure the
boot fully engages the spark plug’s tip.
Recommended Spark Plug Replacement:
AutoLite
63
Champion
RN9YC
Bosch
WR7DS
Torch
F6RTC
BATTERY SERVICE
To ensure the battery remains charged, the generator
should be started every 2 to 3 months and run for a
minimum of 15 minutes. If the generator is stored more
than a year without running, a battery charger may be
needed to recharge the battery.
Battery Replacement
1. Remove the spark plug wire from spark plug.
2. Loosen and remove the nuts on the battery hold-
down plate and remove the plate from the support
rods (see Figure 39).
1
2
3
Figure 39
1 - Nuts
2 - Battery Hold-
2 - Battery Hold-
Down Plate
3 - Support Rods
3. Tip the battery forward slightly to access battery
cables.
4. Disconnect the black negative (-) battery cable from
the battery first.
5. Disconnect the red positive (+) battery cable
second and remove the battery.