Bryant 312AAV/JAV Manuel D’Utilisation

Page de 56
2
A
A
B
[736.9]
[736.9]
29
29
Ø7/8
Ø7/8
[22.2]
[22.2]
ACCESSORY
ACCESSORY
5 15/16
5 15/16
[150.7]
[150.7]
28.39
28.39
[721.2]
[721.2]
Ø7/8
Ø7/8
[22.2]
[22.2]
ACCESSORY
ACCESSORY
14 7/8
14 7/8
[337.3]
[337.3]
(BOTH SIDES)
(BOTH SIDES)
Ø7/8
Ø7/8
[22.2]
[22.2]
ACCESSORY
ACCESSORY
Ø7/8
Ø7/8
[22.2]
[22.2]
ACCESSORY
ACCESSORY
Ø1 3/4
Ø1 3/4
[44.5]
[44.5]
GAS ENTRY
GAS ENTRY
Ø1/2
Ø1/2
[12.7]
[12.7]
THERMOSTAT WIRE ENTRY
THERMOSTAT WIRE ENTRY
22 1/16
22 1/16
[560]
[560]
SIDE INLET
SIDE INLET
(BOTH SIDES)
(BOTH SIDES)
11 7/16
11 7/16
[290.7]
[290.7]
9 11/16
9 11/16
[245.4]
[245.4]
[197.8]
[197.8]
7 13/16
7 13/16
Ø7/8
Ø7/8
[22.2]
[22.2]
J.BOX PROVISION
J.BOX PROVISION
Ø7/8
Ø7/8
[22.2]
[22.2]
JUNCTION BOX
JUNCTION BOX
LOCATION
LOCATION
Ø1 3/4
Ø1 3/4
[44.5]
[44.5]
GAS ENTRY
GAS ENTRY
1 15/16
1 15/16
[49.2]
[49.2]
1
[25.4]
[25.4]
1 1/4
1 1/4
[31.8]
[31.8]
29 9/16
29 9/16
[750.7]
[750.7]
1 15/16
1 15/16
[49.2]
[49.2]
5 5/8
5 5/8
[143.3]
[143.3]
5 7/16
5 7/16
[138.5]
[138.5]
6 13/16
6 13/16
[172.3]
[172.3]
Ø1/2
Ø1/2
[12.7]
[12.7]
THERMOSTAT WIRE ENTRY
THERMOSTAT WIRE ENTRY
19
19
[481.7]
[481.7]
OUTLET
OUTLET
D
21.6
21.6
[549.5]
[549.5]
BOTTOM INLET
BOTTOM INLET
C
33 1/4
33 1/4
[843.9]
[843.9]
9 9/16
9 9/16
[243.3]
[243.3]
3/4
3/4
[19.1]
[19.1]
5 7/8
5 7/8
[148.5]
[148.5]
3 7/16
3 7/16
[86.8]
[86.8]
9 7/8
9 7/8
[250.7]
[250.7]
27 3/4
27 3/4
[704.7]
[704.7]
2 5/16
2 5/16
[59]
[59]
FRONT OF CASINGFR
O
N
O
C
A
SI
N
G
TOP OF CASING
TOP OF CASING
4 13/16
4 13/16
[122.2]
[122.2]
27 3/4
27 3/4
[704.7]
[704.7]
5 7/8
5 7/8
[148.5]
[148.5]
8 5/8
8 5/8
[219]
[219]
5 1/2
5 1/2
[140.3]
[140.3]
8 7/16
8 7/16
[213.5]
[213.5]
FRONT OF CASINGFR
O
N
O
C
A
SI
N
G
TOP OF CASING
TOP OF CASING
6.1
6.1
[155.7]
[155.7]
2 1/16
2 1/16
[51.6]
[51.6]
5.1
5.1
[130.5]
[130.5]
1.7
1.7
[43.5]
[43.5]
Ø7/8
Ø7/8
[22.2]
[22.2]
ACCESSORY (2)
ACCESSORY (2)
AIR FLOW
AIR FLOW
AIR FLOW
AIR FLOW
BOTTOM RETURN
BOTTOM RETURN
WIDTH
WIDTH
AIR FLOW
AIR FLOW
KNOCK OUTS FOR
KNOCK OUTS FOR
VENTING(5 
VENTING(5 
PLACES)
PLACES)
A10290
NOTES:
1. Two additional 7/8---in. (22 mm) diameter holes are located in the top plate.
2. Minimum return---air openings at furnace, based on metal duct. If flex duct is used, see flex duct manufacturer’s recommendations for equivalent diameters.
a. For 800 CFM---16---in. (406 mm) round or 14 1/2 x 12---in. (368 x 305 mm) rectangle.
b. For 1200 CFM---20---in. (508 mm) round or 14 1/2 x 19 1/2---in. (368 x 495 mm) rectangle.
c. For 1600 CFM---22---in. (559 mm) round or 14 1/2 x 22 1/16---in. (368 x 560mm) rectangle.
d. For airflow requirements above 1800 CFM, see Air Delivery table in Product Data literature for specific use of single side inlets. The use of both side inlets,
a combination of 1 side and the bottom, or the bottom only will ensure adequate return air openings for airflow requirements above 1800 CFM.
Fig. 1 -- Dimensional Drawing
Table 1 – Dimensions -- In. (mm)
FURNACE SIZE
A
CABINET
WIDTH
B
OUTLET WIDTH
C
TOP &
BOTTOM FLUE
COLLAR
D
BOTTOM
INLET WIDTH
VENT
CONNECTION
SIZE
SHIP WT
LB (KG)
ACCESSORY
FILTER MEDIA
CABINET
045---08/024045
14---3/16 (360)
12---9/16 (319)
9---5/16 (237)
12---11/16 (322)
4 (102)
104 (47)
16 (406)
045---12/036045
14---3/16 (360)
12---9/16 (319)
9---5/16 (237)
12---11/16 (322)
4 (102)
107 (49)
16 (406)
070---08/024070
14---3/16 (360)
12---9/16 (319)
9---5/16 (237)
12---11/16 (322)
4 (102)
111 (50)
16 (406)
070---12/036070
14---3/16 (360)
12---9/16 (319)
9---5/16 (237)
12---11/16 (322)
4 (102)
115 (52)
16 (406)
070---16/048070
17---1/2 (445)
15---7/8 (403)
11---9/16 (294)
16 (406)
4 (102)
126 (57)
16 (406)
090---14/042090
17---1/2 (445)
15---7/8 (403)
11---9/16 (294)
16 (406)
4 (102)
127 (58)
16 (406)
090---16/048090
21 (533)
19---3/8 (492)
13---5/16 (338)
19---1/2 (495)
4 (102)
140 (64)
20 (508)
090---20/060090
21 (533)
19---3/8 (492)
13---5/16 (338)
19---1/2 (495)
4 (102)
146 (66)
20 (508)
110---12/036110
17---1/2 (445)
15---7/8 (403)
11---9/16 (294)
16 (406)
4 (102)
135 (61)
16 (406)
110---16/048110
21 (533)
19---3/8 (492)
13---5/16 (338)
19---1/2 (495)
4 (102)
146 (66)
20 (508)
110---22/066110
21 (533)
19---3/8 (492)
13---5/16 (338)
19---1/2 (495)
4 (102)
152 (69)
20 (508)
135---16/048135
21 (533)
19---3/8 (492)
13---5/16 (338)
19---1/2 (495)
4 (102)
{
149 (68)
20 (508)
135---22/066135
24---1/2 (622)
22---7/8 (581)
15---1/16 (383)
23 (584)
4 (102)
{
163 (74)
24 (610)
155---20/060155
24---1/2 (622)
22---7/8 (581)
15---1/16 (383)
23 (584)
4 (102)
{
170 (77)
24 (610)
*135 and 155 size furnaces require a 5 or 6---in. (127 or 152 mm) vent. Use a vent adapter between furnace and vent stack. See Installation Instructions for
complete installation requirements.
312AA
V