9. Trouble Shooting Guide 
Optical Engine 
No. 
Item 
Trouble Shooting Guide 
1 Brightness 
1. Change 
lamp 
2.  Check overfill size: If overfill too large, re-install SL and AL to 
ensure correct position 
2 Uniformity 
1.  If Uniformity is within 3% of spec: Change lamp 
2.  Check FM installation 
3.  Check overfill size: If overfill too small, re-install SL and AL 
to ensure correct position 
3 FOFO 
Contrast 
1. Clean 
DMD 
2. Clean 
PL 
4 ANSI 
Contrast 
1. Clean 
PL 
2. Clean 
DMD 
3. Change 
PL 
Color 
Check CW 50% point. Replace CW if necessary 
Color Uniformity 
Change CM 
7 Blue 
Edge 
1.  Readjust LP: Make sure the LP end is touching with 
DMD_HSG Datum 
2.  Check LP: If LP is crushed, replace with new LP 
8 Blue/Purple 
Border 
1.  re-install SL and AL to ensure correct position 
2.  Check FM installation 
9 Focus 
1.  Change Projection Lens 
2.  Put shim metal between upper side of DMD and DMD datum 
10 Dust 
Clean 
DMD 
11 
Horizontal/Vertical 
Strips 
1.  Check connector between FPC and M/B 
2.  Re-install DMD with FPC 
3.  Check if any pin of C-Spring is missing or damaged 
4.  Change new FPC/C-Spring 
5.  Change new DMD 
12 
Pixel Fail 
Change new DMD