Current sense
Range ......................................   5 mA to 10 A
Resolution ...............................   0.1 mA steps from 5 mA to 99.9 mA 
1 mA steps from 100 mA to 999 mA 
10 mA steps from 1 A to 10 A
Tolerance .................................   ±20%
 Alarm relay control
Quantity/type .................................   1 normally open relay
Connector ......................................   (1) 3.5 mm captive screw connector, 2 pole
Contact rating ................................   24 V, 1 A
 General
Power input
IPL T PCS4 ...............................  Internal 
120 VAC, 50-60 Hz 
15 watts
IPL T PCS4i ...............................  Internal 
220 VAC, 50-60 Hz 
15 watts
Temperature/humidity ....................   Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing 
Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing
Cooling ..........................................   Convection, no vents
Mounting
Rack mount .............................   Yes, with optional 1U rack shelf
Furniture mount ......................   Yes, under-furniture mountable with optional mounting kit
Enclosure type ................................  Metal
Enclosure dimensions .....................   1.7" H x 8.7" W x 9.5" D (1U high, half rack wide) 
(4.3 cm H x 22.0 cm W x 24.1 cm D) 
(Depth excludes connectors.)
Product weight ...............................   2.6 lbs (1.2 kg)
Shipping weight .............................   5 lbs (3 kg)
Vibration ........................................   ISTA 1A in carton (International Safe Transit Association)
Regulatory compliance
Safety
IPL T PCS4 ..........................   CE, c-UL, UL
IPL T PCS4i .........................   CE
EMI/EMC .................................   CE, C-tick, FCC Class A, ICES, VCCI
MTBF .............................................   30,000 hours
Warranty ........................................   3 years parts and labor